Product Overview
The Aplisens ZS-30/1Ex is an intrinsically safe power supply & isolator for two-wire 4–20 mA transmitters used in hazardous areas, with full galvanic separation and a universal supply of 20–253 V AC/DC. For accurate selection and pricing, please call 865-900-8844 or email KSmith@CPSCalibrations.com.
The Aplisens ZS-30/1Ex is an intrinsically safe power supply and isolator designed to power intrinsically safe two-wire transmitters in hazardous areas with a 4–20 mA signal, and to transform that signal through a galvanic separation circuit into standard control signals. The IN, OUT, and SUPPLY circuits are galvanically separated.
- Ex-rated intrinsically safe (hazardous area transmitter interface)
- Universal power supply: 20–253 V AC/DC
- Full galvanic separation: IN–OUT, IN–SUPPLY, OUT–SUPPLY
- Digital calibration of measurement chain IN–OUT
- Accuracy: 0.1%
- DIN rail mounting: TS35 / TS32
Standard version provides an intrinsically safe input circuit supply of 24 VDC. Special versions are available for different output signals.
| Feature | Details |
|---|---|
| Model | ZS-30/1Ex Intrinsically Safe Power Supply & Isolator |
| Power Supply | 20–253 V AC/DC |
| Input Circuit Supply Voltage (UIN) | 24 V |
| Work Input Voltage at Terminals (P+ / P−) | 22.5 V |
| Max Voltage at Input Terminals (P+ / P−) | 25.2 V |
| Input Signal (IIN) | 4–20 mA |
| Maximum Shorting Current of Input Circuit | (27…35) / 100 mA |
| Output Signal Options | 4–20 mA (standard), 0–20 mA, 0–5 mA, 0–5 V, 1–5 V, 0–10 V, 2–10 V |
| Load Resistance (RO) | 4–20 mA / 0–20 mA: 0–500 Ω 0–5 mA: 0–2 kΩ Voltage outputs: ≥ 10 kΩ |
| Accuracy | ≤ 0.1% |
| Power Consumption | ≤ 2 W |
| Test Voltage Between Circuits | 1.5 kV AC, 50 Hz |
| Ambient Temperature | 5…+55 °C |
| Ingress Protection | IP20 |
| Dimensions | 114 × 99 × 22.5 mm |
| Weight | < 0.150 kg |
| Relative Humidity | 30…85% |
For hazardous areas: ZS-30/1Ex provides an intrinsically safe input circuit for the transmitter and galvanic isolation between circuits.
ZS-30/1Ex pricing depends on output configuration. To quote correctly, we typically confirm:
| What We Need | Examples |
|---|---|
| Output Type | Standard 4–20 mA or special output: 0–10V, 1–5V, 0–20mA, 0–5mA |
| Receiving Load (RO) | Confirm your PLC/DAQ/controller input/load matches the selected output resistance requirements |
| Hazardous Area Use | Confirm transmitter type and area classification so we can help validate the correct Ex application |
Ordering procedure: Standard version (UIN = 24 V, IOUT = 4–20 mA) is ZS-30/1Ex. Special version format: ZS-30/1Ex /___ (specify output signal). Call 865-900-8844 or email KSmith@CPSCalibrations.com.
Need help confirming output type, load resistance, or hazardous-area compatibility? Reach out and we’ll help.