Product Overview
The 04 Series single gas monitor is designed to operate for many years with field replaceable sensors and filters. The 04 Series can be operated continuously for up to 9,000 hours on (2) AAA size alkaline batteries (depending on model). The 04 Series has 3 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard.
The replacement sensors are inexpensive, easily field replaceable, and are interchangeable with other popular RKI instruments like the GX-3R, GX-3R Pro, and GasWatch 3. Sensors have a life expectancy of over 3 years and are backed by a 3 year warranty.*
Each 04 Series monitor is impact, dust, and water resistant with an IP-67 ingress protection rating. 04 Series instruments are safe for use in hazardous locations, classified as intrinsically safe ATEX/IECEx and by QPS to U.S. and Canadian standards for Class I, Division 1, Groups A, B, C, and D atmospheres.
* 3 year warranty on material and workmanship including sensors (1 year warranty for Ammonia and Chlorine sensors)
Gases & Detectable Ranges
Hydrogen Sulfide (H₂S): Detection range 0–200 ppm, accuracy ± 5% or ± 2 ppm. Alarm set points: A1: 5 ppm, A2: 30 ppm, A3: 100 ppm. Continuous operation: 9,000 hours.
Carbon Monoxide (CO): Detection range 0–2000 ppm, accuracy ± 5% or ± 5 ppm. Alarm set points: A1: 25 ppm, A2: 50 ppm, A3: 1200 ppm. Continuous operation: 9,000 hours.
Oxygen (O₂): Detection range 0–40% Vol., accuracy ± 0.5%. Alarm set points: A1: 19.5 Vol., A2: 18.0 Vol., A3: 23.5 Vol. Continuous operation: 3,000 hours.
Ammonia (NH₃): Detection range 0–400 ppm, accuracy ± 10% or ± 5% full scale. Alarm set points: A1: 25 ppm, A2: 35 ppm, A3: 300 ppm. Continuous operation: 3,000 hours.
Chlorine (Cl₂): Detection range 0–20 ppm, Alarm set points: A1: 1.0 ppm, A2: 2.0 ppm, A3: 10.0 ppm.
Specifications
Sample Method: Diffusion
Response Time: T90 in 30 seconds
Alarm Types: Gas alarm, trouble alarm (1st, 2nd, 3rd adjustable), OVER alarm, STEL, and TWA.
Alarm Methods: Flashing LED, intermittent buzzer, and vibration.
Battery Options: Alkaline dry cell (2 AAA batteries).
Operating Temp. & Humidity: -4°F to 122°F (-20°C to +50°C), 0-90% RH non-condensing.
Warranty: 3 years (1 year for Ammonia and Chlorine sensors).