Product Overview
The Beacon 410A is a highly configurable, microprocessor-based, flexible and easy-to-use 4 channel gas monitoring controller. It simultaneously displays the gas type, readings, and status for four channels of gas detection. It can monitor any combination of direct connect sensors (LEL, O2, CO2, and toxic gas sensors), as well as any 4-20mA transmitter.
Each channel has up to three fully configurable alarm points. A built-in silenceable audible alarm alerts you to alarm conditions. Each channel also has two dedicated fully configurable relays, and there is a bank of common relays as well. The common relays can optionally be configured as additional relays allowing up to 3 alarm relays per channel. Each channel provides a 4-20mA output signal. A digital Modbus interface for remote logging of data via a Modbus network is standard. A Min-Max feature retains high & low peak readings for review at any time.
A fully configurable, high visibility strobe is available as an option. The unit can be powered from 115/220 VAC, or an external 24 VDC source. A trickle charging battery backup feature with battery assembly is also available as an option.
All features and functions of the Beacon 410A are controlled by easy-to-use menus on the OLED display. All features including form-C relay contacts of the Beacon 410A are built into the unit so you never need to purchase or maintain any “add-on” cards or components.
Related Services
- Design, Consultations, and Engineering
- Installation
- Start-up
- Training
- System Maintenance
Please contact CPS Calibrations at 865-900-8844 or SFarmer@cpscalibrations.com for more information.
Category | Details |
---|---|
Physical Dimensions | Height: 12.5”, Width: 11”, Depth: 6.4” |
Enclosure | NEMA 4X non-metallic for indoor and outdoor locations |
Conduit Connection | 3/4” NPT conduit hubs, 4 provided, for sensor, power, & relay wiring |
Wiring Termination | Screw type terminal block, 14 gauge max |
Power | 115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available |
Controls | UP/YES, DOWN/NO, ESCAPE, ENTER buttons; external reset and On/Off toggle switch |
Operating Temperature | -4°F to 122°F (-20°C to 50°C) |
Storage Temperature | -4°F to 158°F (-20°C to 70°C) |
Relative Humidity | 0 – 80% RH (non-condensing) |
Inputs | Direct wired LEL, Oxygen, CO, H2S, CO2 sensors; 4-20mA transmitters (up to 8,000 feet) |
Outputs | Programmable relays, 4-20mA outputs, RS-485 Modbus data |
Display | Four-line OLED display |
Audible Alarm | 94 dB built-in alarm; pulsing for gas alarm, steady for fail |
Warranty | One year materials and workmanship |
Partial List of Detectable Gases | Ammonia (NH3), Arsine (AsH3), Boron Trichloride (BCl3), and more. Contact CPS Calibrations for a full list at 865-900-8844. |