Aplisens Rail-mounted smart temperature transmitters type LI-24L and LI-24/Ex

Aplisens

Write a Review

Configured Per Application – Call for Quote

SKU:
LI-24L and LI-24/Ex

Product Overview

Pricing Available Upon Request
The Aplisens LI-24L Rail-Mounted Smart Temperature Transmitter converts RTD, thermocouple, mV, or resistance inputs into a 4–20 mA output with HART and supports dual-channel temperature functions. For accurate selection and pricing, please call 865-900-8844 or email KSmith@CPSCalibrations.com.

The Aplisens LI-24L is a rail-mounted (TS-35) smart temperature transmitter designed to convert RTD resistance or thermocouple voltage (and other supported inputs) into a standard 4–20 mA signal with HART. It includes two separate measuring channels enabling measurement of temperature difference, average, average with redundancy, and max/min temperature. Configuration is performed with a PC + HART/USB converter using Raport 2.

  • Output: 4–20 mA + HART
  • Inputs: RTD (Pt/Ni/Cu), thermocouples (K, J, S, B, N, T, R, E), mV / resistance ranges
  • Cold junction compensation: internal / external (Pt100) / constant temperature
  • Diagnostics: autodiagnostic system
  • Safety option: SIL2/SIL3 safety version available
  • Hazardous area option: intrinsically safe version available
  • Mounting: DIN rail TS-35

Need dual-sensor logic (average, redundancy, max/min) or help selecting RTD vs TC? Call us and we’ll match the correct configuration.

Feature Details
Model LI-24L Rail-Mounted Smart Temperature Transmitter
Output Signal 4–20 mA + HART
Power Supply 10…36 VDC (standard / Safety)
Ex / Safety Ex: 10…30 VDC
Ambient Temperature -40…+85°C
Accuracy ±0.1%
Time Constant 0.2…1 s
Electronic Damping 0…30 s
Max Wire Resistance 500 Ω
Alarm Signal 21.6 mA or 3.75 mA (or user setting)
Sensor Current 0.25 mA
Dimensions (W×H×D) 12.5 mm × 99 mm × 114.5 mm

The LI-24L supports multiple sensor types and input ranges; configuration is performed via HART using Raport 2 software.

LI-24L pricing depends on version (standard / Ex / Safety) and configuration. To quote correctly, we typically confirm:

What We Need Examples
Version Standard, Ex, Safety (SIL2/SIL3), or Safety Ex
Sensor Type RTD (Pt10/Pt50/Pt100/Pt1000/Ni100/Cu100) or TC (K/J/T/N/E/R/S/B)
Channel Use Single sensor, 2× RTD, 2× thermocouple, difference / average / redundancy / max/min
Measuring Range Your required temperature range (and alarm behavior)
Alarm Output 21.6 mA / 3.75 mA or custom user setting

Ordering format example: LI-24L / ___ / ___ / ___ / ___ (version / sensor type / measuring range / alarm).
Call 865-900-8844 or email KSmith@CPSCalibrations.com and we’ll quote the correct configuration.