Product Overview
The Aplisens APR-2000ALW is configured per application (DP range, process connection type, wetted materials, approvals, and options like HS / Safety). To ensure proper selection and accurate pricing, please call 865-900-8844 or email KSmith@CPSCalibrations.com for a custom quote.
The Aplisens APR-2000ALW is a smart differential pressure transmitter for measurement of differential pressure of gases, vapours, and liquids. It provides a 4–20 mA output with HART and supports a local backlit display with configuration via local keys.
- Output: 4–20 mA + HART (HART 5 / HART 7)
- Accuracy: 0.075% of calibrated range (tighter accuracy available on request)
- Static pressure limit: up to 1000 bar (configuration dependent)
- Process connections: multiple styles (C, CH, GP, PN, 1/2" NPTM) and diaphragm seal options
- Approvals: hazardous-area options available (ATEX / IECEx / FM, etc., configuration dependent)
- Materials: wetted parts SS316L standard; optional Hastelloy / Tantalum / gold-plated diaphragm
Tell us your required DP range, static pressure, process connection, and approvals and we’ll help pick the correct build and send a formal quote.
| Feature | Details |
|---|---|
| Model | Aplisens APR-2000ALW |
| Type | Smart Differential Pressure Transmitter |
| Output / Communication | 4–20 mA + HART (HART 5 / HART 7) |
| Accuracy | ±0.075% of calibrated range (±0.05% special version; tighter on request) |
| Measuring Ranges (Nominal FSO) | 0…70 bar; 0…16 bar; 0…2.5 bar; 0…1 bar; 0…0.25 bar; -0.5…0.5 bar; -100…100 mbar; -5…70 mbar; -25…25 mbar; -7…7 mbar |
| Rangeability | Up to 25:1 (range dependent) |
| Static Pressure Limit | C-type: up to 1000 bar (other limits depend on configuration / version); GP / 1/2" NPT versions have lower static pressure limits (range dependent) |
| Power Supply (typical) | Standard: 10…55 VDC (other versions depend on approval type) |
| Resistance for HART Communication | Minimum 240 Ω |
| Ambient Temperature | -25…85°C (approval/version dependent) |
| Medium Temperature | -25…120°C (above 120°C typically requires impulse line or diaphragm seals) |
| Protection Rating | IP66 / IP67 (version dependent) |
| Wetted Materials | SS316L standard; optional Hastelloy C276 / Tantalum / gold-plated diaphragm (configuration dependent) |
Communication and configuration are available through HART communicators or PC (HART/USB interface) depending on your workflow.
APR-2000ALW pricing depends on configuration. To quote correctly, we typically confirm:
| What We Need | Examples |
|---|---|
| DP Range | Choose nominal range (FSO) and set/calibrated range (4 mA to 20 mA points) |
| Static Pressure | 250 / 320 / 413 / 1000 bar (configuration dependent) |
| Process Connection Type | /C (manifold mount), /CH (C-type rotated 90°), /GP (G1/2"), /PN (1/4" NPT F), /1/2"NPTM, or diaphragm seal option |
| Wetted Materials | SS316L standard; options (for certain connections) include Hastelloy / Tantalum / gold-plated diaphragm |
| Approvals / Hazardous Area | ATEX / IECEx / FM / XP / IS / Exd options (site dependent) |
| Display & Protocol | /ALW display version; HART revision option as required |
| Stability / Safety Options | /HS ultra-stable (ranges dependent); /Safety SIL2/SIL3 (as required) |
Call 865-900-8844 or email KSmith@CPSCalibrations.com with your DP range, static pressure, connection type, and approvals and we’ll confirm the correct build and provide a formal quote.
Need help selecting the correct DP range, static pressure rating, or connection style? Contact us and we’ll make sure you get the right APR-2000ALW configuration.