Description
The CPS Calibrations 4-Gas Calibration Gas – HCN 10 ppm / CO 50 ppm / CH₄ 2.5% (50% LEL) / O₂ 18.0% is a precision calibration gas mixture designed for the calibration and bump testing of compatible portable and fixed gas detection instruments.
This mixture contains 10 ppm Hydrogen Cyanide (HCN), 50 ppm Carbon Monoxide (CO), 2.5% (50% LEL) Methane (CH₄), and 18.0% Oxygen (O₂), with Nitrogen (N₂) balance.
Available in 34L, 44L, 60L, 66L & 120L cylinders, each cylinder is equipped with a C-10 connection.
Each cylinder includes a QR code for convenient access from a smartphone or other compatible device to the cylinder-specific Safety Data Sheet (SDS) and Certificate of Analysis (COA).
This calibration gas is NIST traceable and produced under quality systems supporting ISO 17034:2016 – Reference Material Production, ISO/IEC 17025:2017 – Chemical Testing, and ISO 9001:2015 – Quality Management.
Hydrogen Cyanide (HCN): 10 ppm
Carbon Monoxide (CO): 50 ppm
Methane (CH₄): 2.5% (50% LEL)
Oxygen (O₂): 18.0%
Balance Gas: Nitrogen (N₂)
Cylinder Sizes: 34L, 44L, 60L, 66L & 120L
Connection: C-10
Shelf Life: 12 Months
Traceability: NIST Traceable
Documentation: Cylinder-Specific SDS & COA via QR Code
Country of Manufacture: USA
Need help confirming the correct calibration gas for your detector?
Call CPS Calibrations at 865-900-8844 or email info@cpscalibrations.com.
| Hydrogen Cyanide (HCN) | 10 ppm |
| Carbon Monoxide (CO) | 50 ppm |
| Methane (CH₄) | 2.5% (50% LEL) |
| Oxygen (O₂) | 18.0% Vol. |
| Balance Gas | Nitrogen (N₂) |
| Available Cylinder Sizes | 34L, 44L, 60L, 66L & 120L |
| Cylinder Connection | C-10 |
| Shelf Life | 12 Months |
| Traceability | NIST Traceable |
| Reference Material Production | ISO 17034:2016 |
| Chemical Testing | ISO/IEC 17025:2017 |
| Quality Management | ISO 9001:2015 |
| Documentation | Cylinder-Specific SDS & Certificate of Analysis (COA) Accessible via QR Code |
| Country of Manufacture | USA |
Common Uses
- Calibration of compatible multi-gas gas detectors
- Bump testing and functional verification
- Portable gas detection equipment
- Fixed multi-gas gas detection systems
- Industrial safety and maintenance programs
Always verify the required calibration gas concentration, regulator, flow rate, and calibration procedure specified by the gas detector manufacturer before use.
Processing Time: Please allow approximately 3 business days for order processing prior to shipment. Lead times may vary depending on availability and order quantity.
Hazardous Material Shipping: Calibration gas cylinders are regulated for transportation as hazardous materials and must be shipped in accordance with applicable carrier and hazardous-material regulations. Available shipping methods and charges may vary based on cylinder size, quantity, destination, and applicable HazMat requirements.
Non-Returnable: Calibration gas cylinders are non-returnable. Please verify the gas concentration, cylinder size, and connection before placing your order.