The Crowcon Xgard Type 2 (XG2) is a flameproof (Ex d) fixed-point detector for toxic gases and oxygen, using the same electrochemical sensor range and 2-wire 4-20mA output as the intrinsically safe Type 1 but in a flameproof junction box for Zone 1 or 2 (Class I, Division 1) areas where an I.S. barrier is not used.
Sensors are plug-in modules, and the long-life oxygen sensor option carries a 2-year lifespan. The UL configurations listed here are supplied in aluminium or 316 stainless steel junction boxes.
How to read the configuration code: each code spells out the build — XG type, then housing and cable entry (A = aluminium, S = 316 stainless steel, N = glass-reinforced (GRP) nylon; 1 = M20, 2 = 1/2" NPT, 4 = 3/4" NPT, 5 = 2× M20), certification (01 = ATEX/IECEx, 02 = UL/cUL, 07 = INMETRO), then the gas code. Every configuration in the dropdown also names its housing, thread, gas, range and certification in full.
Certifications on this page: configurations are listed in UL/cUL, ATEX/IECEx and INMETRO builds. The certification of each configuration is stated in full at the end of its dropdown label — check it before ordering, as certifications are not interchangeable and an ATEX/IECEx or INMETRO build is not a UL/cUL unit.
Common Applications:
Oil & Gas • Petrochemical • Chemical Plants • Water & Wastewater • Steel • Power Generation • Marine & Offshore
Need help selecting the right configuration? Call CPS Calibrations at (865) 900-8844 — every configuration on this page is a factory Crowcon build, and we calibrate what we sell.
- Flameproof (Ex d) for Zone 1 or 2 and Class I, Division 1 areas
- Electrochemical sensors for toxic gases and oxygen, 2-wire 4-20mA (current sink) output
- Long-life oxygen sensor with a 2-year lifespan
- Universal Xgard junction box — sensors and sinters are plug-in, so replacement takes minutes
- Wall or ceiling mounting with no additional brackets
- Many spare parts are common to all Xgard models, keeping spares holding to a minimum
- Junction boxes in polyester-coated aluminium or 316 stainless steel (UL builds)
- Accessories available for duct mounting, sampling and remote gassing
- Spray deflectors and weatherproof caps available for washdown and offshore environments
| Gases & Ranges (listed configurations) | Hydrogen sulfide: 0–25 ppm, 0–50 ppm, 0–100 ppm, 0–200 ppm, 0–5 ppm, 0–10 ppm, 0–20 ppm; Carbon monoxide: 0–50 ppm, 0–100 ppm, 0–200 ppm, 0–250 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm, 0–300 ppm; Hydrogen: 0–200 ppm, 0–2000 ppm, 0–40000 ppm, 0–20000 ppm; Oxygen: 0–25% vol |
| Size | 156 x 166 x 111 mm (6.1 x 6.5 x 4.3 in) |
| Weight | Aluminium: 1 kg (2.2 lbs); 316 stainless steel: 3.1 kg (6.8 lbs) |
| Enclosure material | Aluminium or 316 stainless steel (UL certified builds) |
| Ingress protection | IP65 (IP66 with weatherproof cap) |
| Cable entries | 1 x M20, 1/2" NPT or 3/4" NPT on right-side (3/4" on aluminium boxes) |
| Terminations | 0.5 to 2.5 mm² (20 to 13 AWG) |
| Sensor type | Electrochemical |
| Operating temperature | -20 to +50 °C (-4 to 122 °F), typical |
| Humidity | 0-90% RH non-condensing |
| Repeatability | <2% FSD (typical) |
| Zero drift | <2% FSD per month (typical) |
| Response time | T90 <10 s oxygen; T90 <30 s to 120 s toxic (sensor dependent) |
| Operating voltage | 8-30 V dc |
| Power | 24 mA maximum |
| Electrical output | 2-wire 4-20mA (current sink) |
| Approvals | UL: Class I, Division 1, Groups B, C, D; ATEX: II 2 GD Ex d IIC T6 Gb; IECEx; MED Marine (oxygen only) |
| EMC compliance | EN 50270, FCC Part 15, ICES-003 |
Product Documents & Resources