Crowcon

Crowcon Xgard XG3 Fixed Flammable Gas Detector

(No reviews yet) Write a Review
SKU:
CROWCON-XG3
Availability:
Usually ships in 3 business days
$784.00 - $1,162.00

Sold Out

Frequently bought together:

Description

The Crowcon Xgard Type 3 (XG3) is a flameproof (Ex d) fixed-point detector for flammable gases, using a poison-resistant catalytic bead (pellistor) sensor with a 3-wire mV bridge output for connection to a gas detection control panel.

It covers the standard flammable gases at 0-100% LEL — hydrogen, methane and propane in the UL configurations listed here — and is rated for continuous operation from -40 °C to +80 °C.

How to read the configuration code: each code spells out the build — XG type, then housing and cable entry (A = aluminium, S = 316 stainless steel, N = glass-reinforced (GRP) nylon; 1 = M20, 2 = 1/2" NPT, 4 = 3/4" NPT, 5 = 2× M20), certification (01 = ATEX/IECEx, 02 = UL/cUL, 07 = INMETRO), then the gas code. Every configuration in the dropdown also names its housing, thread, gas, range and certification in full.

Certifications on this page: configurations are listed in UL/cUL, ATEX/IECEx and INMETRO builds. The certification of each configuration is stated in full at the end of its dropdown label — check it before ordering, as certifications are not interchangeable and an ATEX/IECEx or INMETRO build is not a UL/cUL unit.

Common Applications:
Oil & Gas • Petrochemical • Chemical Plants • Water & Wastewater • Steel • Power Generation • Marine & Offshore

Need help selecting the right configuration? Call CPS Calibrations at (865) 900-8844 — every configuration on this page is a factory Crowcon build, and we calibrate what we sell.

  • Flameproof (Ex d) for Zone 1 or 2 and Class I, Division 1 areas
  • Poison-resistant catalytic bead (pellistor) sensor for flammable gases
  • 3-wire mV bridge output for control-panel systems (typical signal 12-15 mV/%LEL CH4)
  • Wide operating temperature: -40 to +80 °C
  • Universal Xgard junction box — sensors and sinters are plug-in, so replacement takes minutes
  • Wall or ceiling mounting with no additional brackets
  • Many spare parts are common to all Xgard models, keeping spares holding to a minimum
  • Junction boxes in polyester-coated aluminium or 316 stainless steel (UL builds)
  • Accessories available for duct mounting, sampling and remote gassing
  • Spray deflectors and weatherproof caps available for washdown and offshore environments
Gases & Ranges (listed configurations) Hydrogen: 0–100% LEL; Ethanol: 0–100% LEL; Ethylene: 0–100% LEL; Methane: 0–100% LEL; Petrol vapour: 0–100% LEL (unleaded); Butane: 0–100% LEL; Propane: 0–100% LEL; Pentane: 0–100% LEL; Toluene: 0–100% LEL; Methanol: 0–100% LEL; Acetylene: 0–100% LEL; Vinyl chloride: 0–100% LEL; Ammonia: 0–25% LEL; Jet fuel: 0–100% LEL; LPG: 0–100% LEL; Hexane: 0–100% LEL
Size 156 x 166 x 111 mm (6.1 x 6.5 x 4.3 in)
Weight Aluminium: 1 kg (2.2 lbs); 316 stainless steel: 3.1 kg (6.8 lbs)
Enclosure material Aluminium or 316 stainless steel (UL certified builds)
Ingress protection IP65 (IP66 with weatherproof cap)
Cable entries 1 x M20, 1/2" NPT or 3/4" NPT on right-side (3/4" on aluminium boxes)
Terminations 0.5 to 2.5 mm² (20 to 13 AWG)
Sensor type Catalytic bead (pellistor)
Operating temperature -40 to +80 °C (-40 to 176 °F)
Humidity 0-99% RH non-condensing
Repeatability <2% FSD (typical)
Zero drift <2% FSD per month (typical)
Response time T90 <15 s (typical)
Operating voltage 2.0 V dc ±0.1 V (bridge)
Power 300 mA (typical)
Electrical output 3-wire mV bridge; typical signal 12-15 mV/%LEL CH4
Approvals UL: Class I, Division 1, Groups B, C, D; ATEX: II 2 GD Ex d IIC T4 Gb / Ex d IIC T6 Gb, Ex tb IIIC; IECEx
EMC compliance EN 50270, FCC Part 15, ICES-003

Product Documents & Resources

  • Xgard XG3 Fixed Flammable Gas Detector Datasheet (PDF)

Document files are being added to this page. Need one now? Email info@cpscalibrations.com and we'll send it straight over.