The FLIR GF77a Fixed-Mount Gas Imaging Camera is an uncooled OGI camera for continuous, automated gas leak monitoring at well sites, compressor stations, and process facilities. Mounted once, it watches for methane and other gas leaks around the clock and alarms through your control system.
The GF77a provides 320 × 240 thermal imaging with thermal sensitivity under 25 mK, in LR (7-8.5 µm) or HR (9.5-12 µm) spectral versions covering methane, hydrocarbons, SF6, ammonia, and more. GigE and RTSP connectivity, ONVIF-friendly integration, and a compact weatherproof housing make it a practical fixed sensor for emissions monitoring programs.
- First uncooled fixed-mount autonomous optical gas imaging camera for continuous leak detection
- Two variants: GF77a-LR (7-8.5 µm) visualizes methane, nitrous oxide, propane, sulfur dioxide, R-134a and R-152a; GF77a-HR (9.5-12 µm) visualizes SF6, ammonia and ethylene
- RTSP and GigE Vision / GenICam compliant with Wi-Fi, so it connects to a network for continuous monitoring and third-party analytics
- FLIR-patented High Sensitivity Mode (HSM) makes gas plumes easier to see
- Radiometrically calibrated — also monitors tank levels and overheating components
- Remote motorized focus and open architecture for integration
- GF77f variant adds an environmental housing for harsh environments (RJ45 connector, fixed focus, 510 × 177 × 229 mm, 5.90 kg); GF77pt variant adds pan/tilt control
- ONVIF compliant (per FLIR launch materials)
Typical Applications
- Continuous emissions monitoring
- Well pads and compressor stations
- Gas processing plants
- Fenceline and safety monitoring
| Model | FLIR GF77a Fixed-Mount Gas Imaging Camera |
| IR Resolution | 320 × 240 (76,800) pixels |
| Thermal Sensitivity/NETD | <25 mK at 30°C (86°F) |
| Spectral Range | FLIR GF77a-LR: 7 to 8.5 µm; FLIR GF77a-HR: 9.5 to 12 µm |
| Detector Type / Pitch | Uncooled microbolometer / 25 µm |
| Field of view (FOV) | GF77a-LR 25° lens: 25° × 19°; 6° lens: 6.4° × 4.9°; GF77a-HR 25° lens: 25° × 19° |
| Focal Length | 25° lens: 18 mm; 6° lens: 74 mm |
| Focus | One-shot contrast, motorized, manual (GF77f: Fixed) |
| Gas Sensitivity [NECL] | GF77a-LR: CH4 ≤100, N2O ≤75, C3H8 ≤400, SO2 ≤30, R-134a ≤20, R-152a ≤100 ppm×m; GF77a-HR: C2H4 ≤20, NH3 ≤20 ppm×m (ΔT = 10°C, distance = 1 m) |
| Primary Gases Detected | LR: Methane, nitrous oxide, propane, sulfur dioxide, R-134a, R-152a. HR: Sulfur hexafluoride, ammonia, ethylene |
| Accuracy | ±5°C (±9°F) for ambient temperature 15°C to 35°C and object temperature above 0°C |
| Object Temperature Range | -20°C to 70°C (-4°F to 158°F) |
| Image Frequency | 30 Hz |
| Spatial Resolution (IFOV) | 1.4 mrad/pixel |
| Visual Resolution | 2592 × 1944 pixels (page); REST API: 640 × 480 / 1280 × 960 pixels |
| Visual Focus and FOV | Fixed, 67.2° diagonal |
| Streaming Resolution | 640 × 480 pixels |
| Encoding | Video streaming – RTSP: H.264 / MPEG4 / MJPEG; GVSP: Uncompressed. Radiometric streaming – RTSP: Compressed JPEG-LS, FLIR radiometric; GVSP: Uncompressed, signal linear, temperature linear, FLIR radiometric |
| Ethernet Communication | GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based FLIR proprietary |
| Ethernet Connector Type | M12 8-pin X-coded, female (GF77f: RJ45, female) |
| Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 |
| Ethernet Type | 10/100Base-T |
| WiFi | IEEE 802.11a/b/g/n |
| Digital Inputs | 2x opto-isolated, Vin (low) = 0-1.5 V, Vin (high) = 3-25 V |
| Digital Outputs | 3x opto-isolated, 0-48 VDC, max. 350 mA; solid-state opto relay, 1x dedicated as Fault output (NC) |
| Power Consumption | 6.8 W at 24 V DC typical; 7.0 W at 48 V DC typical; 7.3 W at 48 V PoE typical |
| External Voltage | Allowed range 18-56 VDC, 8 W max |
| Encapsulation | IP 54 (IEC 60529); IP66 with accessory |
| Operating Temperature | -30°C to 50°C (-22°F to 122°F) |
| Housing Material | Aluminum |
| Size [L × W × H] | 123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in) (GF77f: 510 × 177 × 229 mm) |
| Weight | 0.82 kg (1.8 lbs) (GF77f: 5.90 kg / 13.0 lb) |
| Package Includes | Thermal camera in protective housing; Extra cable glands for auxiliary cables; Printed documentation including the username and password for log in to the web interface of the camera |
| Packaging | Type: cardboard box; Weight: 6.8 kg (15.0 lb); Size: 645 × 207 × 225 mm |
| Pan/Tilt | Optional feature; Control standard – Pelco D |
| Web Interface | Yes |
| Warranty | http://www.flir.com/warranty/ |
| Included | Thermal camera in protective housing, Extra cable glands for auxiliary cables, Printed documentation including the username and password for log in to the web interface of the camera (page Package Includes row — this describes the GF77f housed variant). The bare GF77a datasheet (P/N 86401-0101) lists packaging contents: Infrared camera with lens, Ethernet cable M12 to RJ45F (0.3 m), Antenna for WLAN 2.4/5 GHz. |
Specifications are subject to manufacturer updates. Refer to current FLIR product documentation for complete operating, safety and maintenance requirements.
FLIR Limited Warranty
The FLIR GF77a Fixed-Mount Gas Imaging Camera is covered by FLIR's standard limited warranty: 2 years on parts and labor and 10 years on the infrared detector, when the product is properly registered with FLIR within 60 days of the original retail purchase date.
Warranty eligibility, registration requirements, exclusions, and coverage are subject to FLIR's complete warranty terms.