Description
The NAGCO N10-101-01 Benzene Specific Detector Tubes provide direct-reading measurement of benzene (C6H6) in air using a manual gas sampling pump. The standard measurement range is 0.5–10 ppm using three 100 mL pump strokes for a total sample volume of 300 mL.
For applications requiring measurements outside the standard range, the N10-101-01 can also be used from 0.25–5 ppm using six pump strokes or from 1.5–30 ppm using one pump stroke with the appropriate correction factor.
Key Features
- Designed for benzene (C6H6) measurement
- Standard measurement range: 0.5–10 ppm
- Extended measurement ranges: 0.25–5 ppm and 1.5–30 ppm
- Direct-reading colorimetric detector tube
- Standard measurement uses three pump strokes / 300 mL sample volume
- White to brown color change
- Pre-tube helps remove interfering compounds
- No electronic instrument or electrical power required
- Designed for field gas detection and sampling applications
Specifications
- Manufacturer: NAGCO
- Part Number: N10-101-01
- Target Gas: Benzene (C6H6)
- Standard Range: 0.5–10 ppm
- Extended Ranges: 0.25–5 ppm / 1.5–30 ppm
- Standard Pump Strokes: 3
- Standard Sample Volume: 300 mL
- Standard Sample Time: 3 × 3 minutes
- Standard Correction Factor: 1.0
- Precision: ≤ ±12% Relative Standard Deviation
- Humidity: No effect from 0–95% RH
- Temperature Range: 0–40°C (32–104°F)
- Color Change: White → Brown
- Storage Life: 1 year in darkness at 5–25°C (40–77°F); refrigeration preferred
Measurement Ranges
- 0.25–5 ppm: 6 pump strokes / 600 mL / correction factor 0.27
- 0.5–10 ppm: 3 pump strokes / 300 mL / correction factor 1.0
- 1.5–30 ppm: 1 pump stroke / 100 mL / correction factor 4.0
Cross-Sensitivity & Interferences
The N10-101-01 uses a pre-tube to help remove interfering compounds. NAGCO documents cross-sensitivity testing with isobutylene, n-hexane, n-heptane, toluene, m-xylene, methane, carbon monoxide and hydrogen sulfide. Hydrocarbons and similar reducing gases are listed as other possible interferences. Refer to the NAGCO datasheet for complete cross-sensitivity and correction information.
Pump Information
NAGCO recommends using NAGCO detector tubes with NAGCO sampling pumps. CPS Calibrations can assist customers transitioning from another detector tube system with selecting the appropriate NAGCO tube and sampling equipment for their application.
Important: Detector tube readings may be affected by temperature and interfering compounds. Always follow the NAGCO datasheet and pump operating instructions for the specific measurement being performed.
View NAGCO N10-101-01 Benzene Specific Detector Tube Datasheet (PDF)