RKI Instruments

RKI Methane (CH4), 0-9,000 ppm, for M2A & M2A-XL Catalytic Direct Connect Replacement Sensor

Write a Review
SKU:
61-0140RKA
  • RKI 61-0140RKA Methane (CH4) 0-9,000 ppm catalytic direct-connect replacement sensor
  • RKI 61-0140RKA LEL  replacement sensor (representative image)
$345.00

Sold Out

Frequently bought together:

Description

The RKI 61-0140RKA is a genuine RKI catalytic detector designed for Methane (CH4) measurement from 0–9,000 ppm in compatible RKI fixed gas detection systems.

This detector is designed for PPM and low-LEL combustible gas applications and uses catalytic sensing technology. It is a direct-connect detector supplied without a transmitter or junction box.

RKI documentation specifically identifies the 61-0140RKA as the catalytic detector used with the M2A 65-2647RK and M2A-XL 65-2647XL Methane 0–9,000 ppm transmitter configurations.

Important: This is the UL version of the RKI 61-0140RKA detector. The 61-0140RKA-05 is the corresponding CSA/cCSAus version. This sensor should also not be confused with the standard 61-0140RK combustible detector used for 0–100% LEL applications.

For assistance confirming the correct replacement sensor for your RKI gas detection system, contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.

  • Genuine RKI Instruments replacement detector
  • Designed for Methane (CH4)
  • Measurement range: 0–9,000 ppm
  • Designed for PPM and low-LEL combustible applications
  • Catalytic sensing technology
  • Direct-connect configuration
  • UL version
  • For RKI M2A 65-2647RK
  • For RKI M2A-XL 65-2647XL
  • Transmitter not included
  • Junction box not included
  • RKI part number 61-0140RKA
Manufacturer RKI Instruments
Part Number 61-0140RKA
Product Type Direct-Connect Catalytic Detector / Sensor
Target Gas Methane (CH4)
Detection Range 0–9,000 ppm
Application PPM / Low-LEL Combustible Gas Detection
Sensing Technology Catalytic
Connection Direct Connect
Certification Version UL Version
Transmitter Included No
Junction Box Included No

RKI documentation specifically identifies the 61-0140RKA for the following transmitter configurations:

  • RKI M2A 65-2647RK – Methane (CH4), 0–9,000 ppm
  • RKI M2A-XL 65-2647XL – Methane (CH4), 0–9,000 ppm

Important: Several RKI catalytic detectors have similar part numbers but are intended for different ranges or certification versions:

  • 61-0140RKA – Methane (CH4), 0–9,000 ppm, catalytic, UL version
  • 61-0140RKA-05 – Methane (CH4), 0–9,000 ppm, catalytic, CSA/cCSAus version
  • 61-0140RK – Combustible gas, 0–100% LEL, catalytic, UL version
  • 61-0140RK-05 – Combustible gas, 0–100% LEL, catalytic, CSA/cCSAus version

Always verify the complete RKI part number, required measurement range, certification version, and instrument configuration before ordering.

Need help identifying the correct RKI sensor? Contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.

View AllClose

From the CPS Blog