RKI 10.6 eV PID VOC, 0-4,000 ppm, for GX-6000 & GX-6100 Replacement Sensor
- SKU:
- PID-002LA
- MPN:
- PID-002L
Description
The RKI PID-002LA is a genuine RKI 10.6 eV Photoionization Detector (PID) replacement sensor designed for compatible RKI GX-6000 and RKI GX-6100 portable multi-gas monitors.
The PID-002LA provides high-range VOC detection from 0–4,000 ppm using a 10.6 eV PID lamp.
Replacement for PID-002L: RKI changed the replacement sensor part number from PID-002L to PID-002LA when the full-scale measurement range was updated from 0–6,000 ppm to 0–4,000 ppm. PID-002LA is the current replacement sensor listed by RKI.
The range change reflects RKI's updated specification for the reliable measurement capability of the 10.6 eV high-range PID sensor.
Important: The PID-002LA is the complete PID sensor assembly. RKI part number 51-1503 is the replacement PID lamp used with this sensor and is sold separately.
For assistance confirming the correct PID sensor for your RKI instrument, contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.
- Genuine RKI Instruments replacement PID sensor
- Current replacement for discontinued PID-002L
- 10.6 eV Photoionization Detector (PID)
- Detects volatile organic compounds (VOCs)
- Measurement range: 0–4,000 ppm
- Compatible with RKI GX-6000
- Compatible with RKI GX-6100
- Complete PID sensor assembly
- Replacement lamp available separately as RKI part 51-1503
| Manufacturer | RKI Instruments |
| Current Part Number | PID-002LA |
| Previous Part Number | PID-002L |
| Sensor Type | Photoionization Detector (PID) |
| Lamp Energy | 10.6 eV |
| Target | Volatile Organic Compounds (VOCs) |
| Current Measurement Range | 0–4,000 ppm |
| Previous PID-002L Range | 0–6,000 ppm |
| Replacement Lamp | RKI 51-1503, 10.6 eV |
| Compatible Instruments | RKI GX-6000, RKI GX-6100 |
RKI documentation identifies the current PID-002LA for:
- RKI GX-6000 – 10.6 eV high-range PID VOC configuration
- RKI GX-6100 – 10.6 eV high-range PID VOC configuration
Current Sensor: PID-002LA
Replaces: PID-002L
Technology: Photoionization Detector (PID)
Lamp: 10.6 eV
Current Range: 0–4,000 ppm VOC
PID-002L Replacement: Customers replacing an older PID-002L 0–6,000 ppm sensor should use the current PID-002LA replacement sensor. RKI revised the specified full-scale range to 4,000 ppm.
Important: RKI offers several PID sensor configurations with different ranges and lamp energies. Verify the existing sensor and required application before ordering.
Need help confirming compatibility? Contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.