RKI Methane (CH4), 0-100% Volume, for GX-2003, GX-2012, Gas Tracer & GX-6100 TC Replacement Sensor
- SKU:
- TE-7561
Description
The RKI TE-7561 is a genuine RKI thermal conductivity (TC) replacement sensor used for high-concentration combustible-gas measurement in compatible RKI portable gas detectors.
The TE-7561 provides %Volume combustible-gas detection and is specified by RKI for the GX-2003, GX-2012, Gas Tracer and GX-6100. For methane applications, the sensor provides a measurement range of 0–100% Volume Methane (CH4).
Unlike a catalytic %LEL sensor, the TE-7561 uses a thermal conductivity element. Changes in thermal conductivity caused by the presence of combustible gas alter the sensor element's electrical characteristics, allowing the instrument to calculate and display the gas concentration.
Important: The TE-7561 is the %Volume sensor and should not be confused with the separate catalytic %LEL or ppm combustible-gas sensors used in these instruments.
For assistance confirming the correct replacement sensor for your RKI instrument, contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.
- Genuine RKI Instruments replacement sensor
- Thermal conductivity (TC) sensing technology
- Designed for high-concentration combustible-gas measurement
- Methane range: 0–100% Volume
- Compatible with RKI GX-2003
- Compatible with RKI GX-2012
- Compatible with RKI Gas Tracer
- Compatible with RKI GX-6100
- Direct replacement for RKI part number TE-7561
| Manufacturer | RKI Instruments |
| Part Number | TE-7561 |
| Product Type | Replacement Gas Sensor |
| Sensing Technology | Thermal Conductivity (TC) |
| Application | %Volume Combustible Gas Detection |
| Methane (CH4) Range | 0–100% Volume |
| Compatible Instruments | GX-2003, GX-2012, Gas Tracer, GX-6100 |
RKI's 2026 documentation identifies the TE-7561 for the following instruments:
- RKI GX-2003 – %Volume combustible-gas configuration
- RKI GX-2012 – %Volume combustible-gas configuration
- RKI Gas Tracer – %Volume combustible-gas configuration
- RKI GX-6100 – compatible %Volume combustible-gas configuration
Sensor function:
- TE-7561 – Thermal Conductivity (TC), %Volume combustible gas
- Methane (CH4) – 0–100% Volume range
Important: The TE-7561 is intended for %Volume measurements. It is not the same sensor as the catalytic sensor used for %LEL measurement or the MOS/catalytic sensor used for ppm-level combustible-gas detection.
Always verify the instrument configuration and required measurement range before ordering.
Need help confirming compatibility? Contact CPS Calibrations at 865-900-8844 or info@cpscalibrations.com.