The Crowcon XgardIQ is an intelligent, versatile fixed gas detector and transmitter in a 316 stainless steel enclosure, with a bright OLED display and a +Ve Safety indicator that shows at a glance — and from a distance — that the detector is operating soundly. It is a universal transmitter: plug in the XgardIQ sensor module for the gas you need, and the auto-configure function uploads the correct gas type, range, units and alarm levels, while auto-sense detects whether your control system is a 4-20mA current sink or source.

The transmitters listed here are supplied with NO sensor module fitted (the ZZ in the part number) — choose the module for your gas from the Crowcon XgardIQ Sensor Modules product, linked below. Modules hot-swap in seconds with the tool provided, with no hot-work permit, so a pre-calibrated spare keeps the point protected while the removed module is calibrated in a safe area. Configurations listed here are English-display builds with ATEX/IECEx, INMETRO or no hazardous-area certification, exactly as stated in each configuration — Crowcon does not offer this transmitter in a UL/CSA configuration in the current range.

How to read the configuration code: XIQ-ZZ = transmitter with no sensor module fitted; S1 = M20 cable entry, S2 = 1/2" NPT (316 stainless steel either way); 000 = no hazardous-area certification, 011 = ATEX/IECEx, 012 = INMETRO; H = HART fitted, R = alarm & fault relay outputs fitted; final A = English display. Every configuration in the dropdown also spells out its entry, certification and options in full.

You also need a sensor module: this transmitter is supplied with no module fitted. Order the module for your gas from the Crowcon XgardIQ Sensor Modules — pellistor, electrochemical and infrared modules cover flammable gases, toxic gases and oxygen.

Common Applications:
Oil & Gas • Petrochemical • Chemical Plants • Water & Wastewater • Steel • Power Generation • Marine & Offshore

Need help selecting the right configuration? Call CPS Calibrations at (865) 900-8844 — every configuration on this page is a factory Crowcon build, and we calibrate what we sell.

  • Hot-swap sensor modules — removed or replaced in seconds using the tool provided, with no hot-work permit or special tools
  • Auto-configure function detects the plugged-in module and uploads gas type, range, units and alarm levels
  • Auto-sense function detects 4-20mA current sink or source control systems, saving time and wiring faults
  • Bright, clear OLED display shows gas level and status even in dark locations
  • +Ve Safety (Positive Safety) indicator confirms the detector is operating soundly at a glance and from a distance
  • Non-intrusive calibration and button operation — no special magnets or tools needed in the hazardous area
  • Smart Bump and Speedy Bump Test verify sensor health following simple on-screen instructions, with automatic bump-test due reminders
  • Calibration-due warning automatically reminds the user when calibration falls due
  • Sensor range selection — set the full-scale range of the sensor via the display menu to suit the location
  • Event log function stores alarm, fault and maintenance events, viewable on screen and downloadable to a PC
  • Remote sensor option for improved probability of detection
  • Optional alarm & fault relays and HART 7 communications
  • SIL2 certified (IEC 61508 / EN 50402 functional safety)
Enclosure material 316 stainless steel
Size 278 x 140 x 89 mm (10.9 x 5.5 x 3.5 in) — transmitter
Weight 4.1 kg (9 lbs)
Cable gland entries 3x M20 or 2x 1/2" NPT (stopping plug fitted to left-side and lower-right entries)
Ingress protection IP66 (EN 60529)
Operating voltage 14-30 V DC
Power <4 W
Output 3-wire 4-20mA (auto-detect sink/source), NAMUR NE43 compliant, configurable warning/fault signals; RS-485 Modbus RTU; HART 7 over 4-20mA and local I.S. test points (optional, per configuration)
Relay output (optional, per configuration) Alarm 1, Alarm 2, Fault — SPDT contacts 5A, 230Vac; configurable energised/de-energised, latching/non-latching, rising/falling, on/off delays
Display OLED main display 128 x 64 pixels, yellow text on black; +Ve Safety LED; amber, red and green status LEDs
Event logging Built-in alarm, fault and maintenance events log
Operating temperature -40°C to +75°C (-40°F to +167°F) — refer to the sensor module for sensor operating temperature
Accuracy Repeatability +/- 2% FSD; zero drift < +/- 2% FSD per year
EMC compliance EN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4
Functional safety SIL2 certified — IEC 61508, EN 50402
Approvals (per configuration) ATEX / IECEx: Ex db ia IIC T4 Gb (Zone 1 & 2, Zone 21 & 22) or INMETRO, as stated in each configuration; uncertified configurations are also listed. No UL/CSA configuration is offered in this range
Sensor module NOT included — transmitter supplied with no module fitted; order a Crowcon XgardIQ Sensor Module for your gas separately