Crowcon XgardIQ Fixed Gas Detector Transmitter
- SKU:
- CROWCON-XIQ-TX
- Availability:
- Usually ships in 3 business days
Description
The Crowcon XgardIQ is an intelligent, versatile fixed gas detector and transmitter in a 316 stainless steel enclosure, with a bright OLED display and a +Ve Safety indicator that shows at a glance — and from a distance — that the detector is operating soundly. It is a universal transmitter: plug in the XgardIQ sensor module for the gas you need, and the auto-configure function uploads the correct gas type, range, units and alarm levels, while auto-sense detects whether your control system is a 4-20mA current sink or source.
The transmitters listed here are supplied with NO sensor module fitted (the ZZ in the part number) — choose the module for your gas from the Crowcon XgardIQ Sensor Modules product, linked below. Modules hot-swap in seconds with the tool provided, with no hot-work permit, so a pre-calibrated spare keeps the point protected while the removed module is calibrated in a safe area. Configurations listed here are English-display builds with ATEX/IECEx, INMETRO or no hazardous-area certification, exactly as stated in each configuration — Crowcon does not offer this transmitter in a UL/CSA configuration in the current range.
How to read the configuration code: XIQ-ZZ = transmitter with no sensor module fitted; S1 = M20 cable entry, S2 = 1/2" NPT (316 stainless steel either way); 000 = no hazardous-area certification, 011 = ATEX/IECEx, 012 = INMETRO; H = HART fitted, R = alarm & fault relay outputs fitted; final A = English display. Every configuration in the dropdown also spells out its entry, certification and options in full.
You also need a sensor module: this transmitter is supplied with no module fitted. Order the module for your gas from the Crowcon XgardIQ Sensor Modules — pellistor, electrochemical and infrared modules cover flammable gases, toxic gases and oxygen.
Common Applications:
Oil & Gas • Petrochemical • Chemical Plants • Water & Wastewater • Steel • Power Generation • Marine & Offshore
Need help selecting the right configuration? Call CPS Calibrations at (865) 900-8844 — every configuration on this page is a factory Crowcon build, and we calibrate what we sell.
- Hot-swap sensor modules — removed or replaced in seconds using the tool provided, with no hot-work permit or special tools
- Auto-configure function detects the plugged-in module and uploads gas type, range, units and alarm levels
- Auto-sense function detects 4-20mA current sink or source control systems, saving time and wiring faults
- Bright, clear OLED display shows gas level and status even in dark locations
- +Ve Safety (Positive Safety) indicator confirms the detector is operating soundly at a glance and from a distance
- Non-intrusive calibration and button operation — no special magnets or tools needed in the hazardous area
- Smart Bump and Speedy Bump Test verify sensor health following simple on-screen instructions, with automatic bump-test due reminders
- Calibration-due warning automatically reminds the user when calibration falls due
- Sensor range selection — set the full-scale range of the sensor via the display menu to suit the location
- Event log function stores alarm, fault and maintenance events, viewable on screen and downloadable to a PC
- Remote sensor option for improved probability of detection
- Optional alarm & fault relays and HART 7 communications
- SIL2 certified (IEC 61508 / EN 50402 functional safety)
| Enclosure material | 316 stainless steel |
| Size | 278 x 140 x 89 mm (10.9 x 5.5 x 3.5 in) — transmitter |
| Weight | 4.1 kg (9 lbs) |
| Cable gland entries | 3x M20 or 2x 1/2" NPT (stopping plug fitted to left-side and lower-right entries) |
| Ingress protection | IP66 (EN 60529) |
| Operating voltage | 14-30 V DC |
| Power | <4 W |
| Output | 3-wire 4-20mA (auto-detect sink/source), NAMUR NE43 compliant, configurable warning/fault signals; RS-485 Modbus RTU; HART 7 over 4-20mA and local I.S. test points (optional, per configuration) |
| Relay output (optional, per configuration) | Alarm 1, Alarm 2, Fault — SPDT contacts 5A, 230Vac; configurable energised/de-energised, latching/non-latching, rising/falling, on/off delays |
| Display | OLED main display 128 x 64 pixels, yellow text on black; +Ve Safety LED; amber, red and green status LEDs |
| Event logging | Built-in alarm, fault and maintenance events log |
| Operating temperature | -40°C to +75°C (-40°F to +167°F) — refer to the sensor module for sensor operating temperature |
| Accuracy | Repeatability +/- 2% FSD; zero drift < +/- 2% FSD per year |
| EMC compliance | EN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4 |
| Functional safety | SIL2 certified — IEC 61508, EN 50402 |
| Approvals (per configuration) | ATEX / IECEx: Ex db ia IIC T4 Gb (Zone 1 & 2, Zone 21 & 22) or INMETRO, as stated in each configuration; uncertified configurations are also listed. No UL/CSA configuration is offered in this range |
| Sensor module | NOT included — transmitter supplied with no module fitted; order a Crowcon XgardIQ Sensor Module for your gas separately |