Product Overview
The RKI GX-Force Pumped 4-Gas Monitor is a compact sample-draw gas detector designed for confined-space entry, personal monitoring, leak investigation, and industrial safety applications. Its powerful internal pump provides a sampling range of up to 100 feet, allowing users to remotely check an atmosphere before entering a potentially hazardous area.
The GX-Force can simultaneously monitor the standard confined-space gases: combustible gas (LEL), oxygen (O₂), carbon monoxide (CO), and hydrogen sulfide (H₂S). The instrument combines RKI's compact sensor technology with an internal sample pump in a lightweight, rugged package.
Two operating modes provide additional flexibility. Normal Mode is designed for standard confined-space and safety monitoring, while Leak Check Mode can be used for investigating combustible gas leaks in valves, piping, and other equipment.
The GX-Force also features approximately 30 hours of operation in Normal Mode, USB-C charging and data connectivity, data logging, audible/visual/vibration alarms, field-replaceable sensors and filters, and an IP67 water- and dust-resistant enclosure.
Common Applications:
Confined Spaces • Personal Monitoring • Refineries & Petrochemical • Oil & Gas • Utilities • Water & Wastewater • Fire Services • Construction • Leak Investigation
Need help selecting the right GX-Force configuration?
Call CPS Calibrations at 865-900-8844 or email info@cpscalibrations.com.
Features
- Internal sample pump with up to 100-foot sampling range
- Simultaneously monitors up to four gases
- Detects combustible gas (LEL), O₂, CO and H₂S
- Normal Mode for confined-space and general safety monitoring
- Leak Check Mode for combustible gas leak investigation
- Approximately 30 hours of operation in Normal Mode
- Rechargeable lithium-ion battery
- USB Type-C charging and data connection
- Large auto-backlit LCD display
- Audible, visual and vibration alarms
- Data logging capability
- STEL, TWA, peak and over-range monitoring
- User-adjustable calibration and bump-test reminders
- Field-replaceable sensors and filters
- Impact-resistant body
- IP67 water- and dust-resistant design
- Intrinsically safe design
- 3-year manufacturer warranty
What's Included
- RKI GX-Force Gas Monitor
- Rechargeable Lithium-Ion Battery
- Belt Clip
- Tapered Rubber Nozzle
- Selected Charging Configuration
- Selected Sampling Hose/Probe Configuration, if applicable
Specifications
| Sampling Method | Internal sample pump |
| Nominal Pump Flow Rate | 0.5 LPM |
| Minimum Suction Flow Rate | 0.35 L/min |
| Maximum Sampling Range | Up to 100 ft. |
| Gas Channels | Up to 4 gases simultaneously |
| Combustible Gas (LEL) | 0–100% LEL, 1% LEL resolution |
| Oxygen (O₂) | 0–40.0% Vol., 0.1% resolution |
| Carbon Monoxide (CO) | 0–2,000 ppm, 1 ppm resolution |
| Hydrogen Sulfide (H₂S) | 0–200.0 ppm, 0.1 ppm resolution |
| Operating Modes | Normal Mode and Leak Check Mode |
| Response Time | T90 within 30 seconds for CH₄, O₂, CO and H₂S; within 40 seconds for HC combustible gas |
| Display | Digital LCD with backlight |
| Alarms | Audible, visual and vibration |
| Audible Alarm | Approximately 90 dB at 30 cm |
| Data Logging | Maximum storage capacity of 3,600 items; adjustable logging interval |
| Communication | USB 2.0 via USB Type-C connection |
| Battery | Rechargeable lithium-ion |
| Battery Runtime | Approximately 30 hours in Normal Mode at 25°C under non-alarm operation |
| Leak Check Mode Runtime | Approximately 20 hours at 25°C under non-alarm operation |
| Estimated Charge Time | Approximately 8 hours |
| Operating Temperature | -4°F to +122°F (-20°C to +50°C) continuous |
| Operating Humidity | Up to 95% RH, non-condensing |
| Ingress Protection | IP67 |
| Dimensions | Approximately 2.52" W × 6.81" H × 1.85" D |
| Weight | Approximately 9.87 oz. |
| Approvals / Certifications | ATEX, IECEx and QPS C/US intrinsically safe certifications |
| Warranty | 3 years, materials and workmanship |
Downloads