Blog
SENSIT HXG-3P: Pumped Combustible Leak Hunting Indoors and Out
The SENSIT HXG-3P is a pumped combustible gas leak detector: it adds an internal pump to the SENSIT HXG-3, displays ppm and %LEL readings for the same gas, and is built to hunt leaks — following a ppm trace and a tick rate to the source, indoors and out. It costs $1,324.20 with Standard certification or $1,609 with ATEX certification at CPS Calibrations, with a ship kit (hard case or soft pouch) included at no charge.
Most combustible instruments are read one of two ways, and confusing them caus
…
Oct 29th 2026
SENSIT GOLD G2 and G3: The Leak Investigation Instruments Utilities Actually Carry
The SENSIT GOLD G2 and GOLD G3 are combustible gas investigation instruments built for utility leak work: each one ranges from parts per million (ppm) for finding a leak, through %LEL for classifying it, to %volume for purging and inert-gas work — with an internal pump, bar-hole testing, and toxic-gas and oxygen channels alongside. The G2 (from $1,440.80 at CPS) displays up to 4 gases at once; the G3 (from $3,034) displays up to 5, and adds a 2-speed pump, smart sensors, Bluetooth, and optional
…
Oct 29th 2026
Gas Detection in the Refrigeration Machinery Room: What ASHRAE 15 Requires
ASHRAE Standard 15 requires a refrigeration machinery room to contain a refrigerant detector located where a refrigerant leak would concentrate, and that detector must trigger an audible and visual alarm both inside and outside the room, activate the room's mechanical ventilation, with emergency controls located outside the room. Detection that only sounds a local beep — no outside alarm, no ventilation — does not meet the standard.
Of all the rooms in a cold storage plant, the machinery room is
…
Oct 29th 2026
Freon and Halocarbon Refrigerant Leaks in Cold Storage: The Gas That Pools Low and Displaces Oxygen
Halocarbon refrigerants — R-404A, R-449A, R-134a and their relatives, sold for decades under the Freon name — are heavier than air, so a leak pools low in pits, trenches, and low corners, displaces oxygen, and is effectively odorless at dangerous concentrations. Detecting one takes a refrigerant-specific instrument (infrared or semiconductor): a standard 4-gas monitor does not read refrigerant concentration at all, and its oxygen channel only shows the displacement after the gas has already pool
…
Oct 29th 2026
Grain Elevators and Feed Mills: Fumigant, Smoldering Grain, and Bin-Entry Air
Grain elevators and feed mills face three layered gas jobs: phosphine fumigant in treated bins — exposure limit 0.3 ppm, immediately dangerous at 50 ppm — which must be aerated and clearance-tested before any entry; carbon monoxide from grain that is heating and smoldering in storage; and bin-entry air itself, which must be tested for oxygen (deficient below 19.5%) and toxics from outside, before a worker goes in, under OSHA's grain-handling standard (1910.272).
A bin looks like the simplest str
…
Oct 29th 2026