Zero vs. Span Calibration: What's the Difference?
Zero calibration sets a gas detector's baseline — it tells the instrument what "no gas" reads like, using clean fresh air, a zero-air cylinder (20.9% oxygen in nitrogen), or pure nitrogen for the oxygen channel — while span calibration sets its accuracy at the top of the scale, exposing the sensors to a certified gas of known concentration and adjusting the reading to match it. A full calibration always does both, zero first: zero without span leaves the instrument's slope unverified
…
Oct 20th 2026
RKI GX-3R vs. GX-3R Pro: What's the Difference?
The difference between the RKI GX-3R and the GX-3R Pro is one sensor channel and the features built around it. The GX-3R ($640) monitors four gases — LEL, O₂, CO, and H₂S. The GX-3R Pro ($1,098) monitors those same four plus a fifth, swappable channel chosen from NH₃, HCN, NO₂, PH₃, SO₂, or CO₂, and adds Bluetooth wireless communication plus man-down and panic alarms. Everything else is shared platform: both are diffusion monitors in an IP66/68 case with roughly 25 hours of rechargeable ba
…
Oct 20th 2026
Why Does My Gas Detector Read Negative?
A gas detector reads negative most often because it was zeroed in air that wasn't clean: if 5 ppm of carbon monoxide is present when the sensor is zeroed, the instrument treats that 5 ppm as its baseline and then reads −5 ppm in genuinely clean air. The other sourced causes are sensor drift from temperature and humidity changes, negative cross-interference from a second gas (an SO₂ sensor exposed to NO₂ is the textbook case), and a sensor at end of life. The fix order is: re-zero in verifi
…
Oct 20th 2026
How Much Does Gas Detector Calibration Cost?
Gas detector calibration costs $55 for a single-gas instrument and $90 for a 4- or 5-gas instrument when you ship the instrument to a calibration lab — those are CPS Calibrations' flat in-house rates for any brand, with a 3–5 business-day turnaround. On-site calibration, where a technician comes to your facility, costs more and is priced by written quote based on fleet size, location, and site conditions. A replacement sensor is never included in a calibration price; if an instrument
…
Oct 20th 2026
When Should You Replace a Gas Detector Sensor — and What Does It Cost?
Replace a gas detector sensor when it can no longer be calibrated back to the certified gas value — the endpoint OSHA's guidance names, when the instrument either fails full calibration or refuses the adjustment and comes out of service. The warning signs arrive earlier, in order: shrinking calibration intervals, sluggish bump-test response, a wandering baseline, and repeated failed calibrations. The cost is usually modest: genuine RKI sensors for the standard channels of a GX-3R are $160
…