Can You Use Expired Calibration Gas? What Actually Goes Wrong
No — you cannot use expired calibration gas for calibration or bump verification, because the reactive components inside drift below their labeled concentrations over time, and spanning a detector with that weakened gas sets the instrument's gain too high, so it over-reads real gas by the same percentage until it is recalibrated with fresh gas. The date on the cylinder is a certification limit, not a suggestion: past it, the concentration is no longer certified, and a calibration performed
…
Oct 20th 2026
PPM vs. %LEL vs. % Volume: How Gas Readings Convert
PPM, %LEL, and % volume measure the same air three different ways: ppm counts molecules per million (1% by volume = 10,000 ppm), % volume states the gas's share of the air outright, and %LEL states the reading as a fraction of that gas's Lower Explosive Limit. They are fully interconvertible for any given gas — 100% LEL methane is 5% by volume is 50,000 ppm — while a toxic like hydrogen sulfide is tracked in ppm because its danger zone, the NIOSH 10 ppm ceiling, is just 0.001% by vol
…
Oct 20th 2026
How Do You Read a Calibration Gas Certificate of Analysis?
You read a calibration gas Certificate of Analysis (CoA) by matching the cylinder in your hand to the certificate line by line: the lot number must match, and you calibrate to each component's certified (actual) concentration — not the nominal concentration the blend was ordered at. Finish with the dates and the traceability statement: the expiry date must be in the future, and the certificate should state what its values are traceable to — on CPS's ISG cylinders the gas is NIST-trac
…
Oct 20th 2026
What Gases Do You Monitor in a Parking Garage? CO and NO₂ Fixed Detection Explained
In an enclosed parking garage you monitor two gases: carbon monoxide (CO), produced mainly by gasoline engines, and nitrogen dioxide (NO₂), the marker gas for diesel exhaust. The International Mechanical Code's ventilation model for enclosed garages (Section 404 in recent editions) runs the exhaust system automatically from CO and NO₂ detectors working together — full ventilation at not less than 0.75 cfm per square foot of floor area, dropping to a standby rate of not less than 0.05 cfm p
…
Oct 20th 2026
Why Do Battery Rooms Need Hydrogen Detection? H₂ Monitoring for Charging Areas
Charging lead-acid batteries vents hydrogen gas, and hydrogen ignites at just 4% by volume in air — its lower explosive limit (LEL). The fire codes written for battery rooms (IFC Section 608 and NFPA 1 Chapter 52) require ventilation designed to hold hydrogen at or below 1% of the room's volume, which is exactly 25% of that LEL — and a hydrogen detector, mounted at the room's highest point and typically alarming at 10% of LEL (0.4% vol), is how a facility proves the ventilation is wo
…
Oct 20th 2026