What Can a Thermal Imaging Camera Find in a Plant? Electrical, Steam, and Insulation Faults
A thermal imaging camera finds the plant faults that announce themselves as temperature before they announce themselves as failures: overheating electrical connections, bearings and couplings heating up as they wear, steam traps failed open or closed, and insulation or refractory that is missing, wet, or worn through. FLIR's stated applications for its professional cameras are electrical inspections, mechanical maintenance, building diagnostics, and preventive maintenance — and at CPS the
…
Oct 20th 2026
How Does a Fixed Gas Detection System Work? Sensors, Controllers, and Alarms
A fixed gas detection system works as a chain: a sensor head mounted at the hazard converts gas concentration into an electrical signal — usually 4-20 mA or RS-485 Modbus — a controller reads every head against its alarm setpoints, and relay contacts act on the result, sounding horns and strobes, starting ventilation, or handing the alarm to a PLC. At CPS that chain starts as small as a single RKI Beacon 110 controller ($1,275) watching one point and scales to an OTIS OI-7432 ($1,930
…
Oct 20th 2026
4-20 mA and Modbus: How Fixed Gas Detectors Talk to Your Plant
A fixed gas detector talks to your plant in one of three ways: a 4-20 mA analog loop, where 4 mA means zero gas and 20 mA means full scale; an RS-485 Modbus link, which carries the reading digitally together with alarm and fault status; or relay contacts, which carry no reading at all — just action at a setpoint. The SENKO SI-200E (from $950) offers both 4-20 mA and RS-485 Modbus on a single head, and OTIS's OI-7432 controller ($1,930) polls up to 32 detector heads over one Modbus daisy ch
…
Oct 20th 2026
What Is the Right RKI Controller for Your Fixed Gas Detection System?
The right RKI controller is the one whose channel count matches your detection points: the Beacon 110 runs one point (listed from $1,275), the Beacon 200 two (from $2,500), the Beacon 410A four (from $2,825), and the Beacon 800 anywhere from one to eight points ($2,835). What actually separates them is the input side — the 110, 200 and 410A accept RKI direct-connect sensors as well as any 4–20 mA transmitter, while the 800 accepts transmitters only — and the output side, where
…
Oct 20th 2026
Where Does Gas Go When It Leaks? Does It Rise, Sink, or Mix?
Where a leaked gas goes is set first by its vapor density against air, with air = 1.0: hydrogen at 0.07 and methane at 0.55 rise and collect at the ceiling, carbon monoxide at 0.97 is nearly neutral and mixes through the room with the moving air, and hydrogen sulfide at 1.19, propane at 1.52, and chlorine at 2.49 sink and pool at floor level. Density is only the starting tendency, though — a gas released hot, under pressure, or into moving air can be carried anywhere the air goes, which is
…