RKI GX-Force Calibration Service: Mail In Your Meter
Mail-in calibration for the RKI GX-Force costs $90 at CPS Calibrations — the published in-house rate for a 4-gas instrument — and covers every channel the meter carries: combustible gas 0–100% LEL, oxygen 0–40.0% vol., carbon monoxide 0–2,000 ppm, and hydrogen sulfide 0–200.0 ppm, with as-found readings recorded before any adjustment, a draw check and filter inspection on the internal sample pump that pulls from up to 100 feet away, a sensor health check, and the meter returned with a certificat
…
Oct 31st 2026
RKI GX-3R Pro Calibration Service: Mail In Your Meter
Mail-in calibration for the RKI GX-3R Pro costs $90 at CPS Calibrations — the published in-house rate for a 4- or 5-gas instrument — and covers every channel the meter carries: the standard four (combustible gas 0–100% LEL, oxygen 0–40.0% vol., carbon monoxide 0–2,000 ppm, hydrogen sulfide 0–200.0 ppm) plus its fifth channel as configured — ammonia 0–400 ppm, hydrogen cyanide 0–30 ppm, nitrogen dioxide 0–20 ppm, phosphine 0–20 ppm, sulfur dioxide 0–100 ppm, or infrared carbon dioxide 0–10,000 pp
…
Oct 30th 2026
Renting vs. Buying Gas Detectors for a Turnaround or Outage: The Real Math
Here is the honest split of this question: the money math — what a rental quote is built from, and the breakeven week where renting starts costing more than buying — already lives in how much it costs to rent gas detectors for a turnaround, and this post does not re-derive a single dollar of it. What this post covers is the half of rent-vs-buy that money cannot settle: the outage itself is a logistics operation — staging and kitting before day one, an issue-and-return desk that reconciles every
…
Oct 29th 2026
What Is T90 Response Time — and Why Does It Decide How You Sample and Test?
T90 is the time a gas sensor takes to reach 90% of its final reading after the gas sample reaches the sensor — and for remote sampling it is only the second of two waits: the sample must first travel the length of the sample line, and only then does the sensor's T90 clock start, so the minimum trustworthy wait at each test point is draw time plus T90 plus a settling margin. Read the display before that total has run and the reading is still climbing — which means a rushed pre-entry test reads lo
…
Oct 29th 2026
Oxygen Depletion vs. Enrichment: Why Both Ends of the O2 Scale Are Dangerous
Oxygen depletion and oxygen enrichment are opposite failures of the same number: normal air is 20.9% oxygen, an atmosphere below 19.5% O2 is oxygen-deficient under OSHA's confined-space definitions (29 CFR 1910.146) and progressively impairs the people breathing it, while an atmosphere above 23.5% O2 is oxygen-enriched and makes ordinary materials ignite easily and burn fiercely — which is why the oxygen channel is the only one on a gas detector that must alarm in both directions, and why it is
…
Oct 29th 2026