Blog
Methane and Carbon Monoxide: The Two Gases That Run Mine Monitoring
Underground coal monitoring runs on two gases: methane, where 30 CFR 75.323 requires equipment deenergized and ventilation corrected at 1.0 percent in a working place and withdrawal at 1.5 percent — and carbon monoxide, the early-warning fire gas, where an atmospheric monitoring system on a belt entry must alert at 5 ppm above the established ambient level and alarm at 10 ppm above it (30 CFR 75.351). Methane is the explosion gas the ventilation plan is built to dilute; CO is the fire gas the be
…
Oct 29th 2026
Gas Monitoring During Brownfield Excavation: What the HASP Requires
On a brownfield excavation that falls under OSHA's HAZWOPER standard (29 CFR 1910.120), the site health and safety plan (HASP) must define an air monitoring program — instrument types, monitoring frequency, and calibration methods — and the standard then requires monitoring at three moments: with direct-reading instruments on initial entry, periodically whenever conditions change, and personally on the workers likely to have the highest exposures once soil starts moving. In practice that program
…
Oct 29th 2026
Sub-Slab Depressurization Telemetry: Proving the System Is Running, 24/7
Sub-slab depressurization telemetry is continuous wireless monitoring of the vacuum a mitigation fan maintains under a slab: a pressure sensor at the sub-slab monitoring point reports through a gateway around the clock, and the moment the pressure field is lost — a dead fan, a tripped breaker, a damaged vent — the system sends a text and email alert to the people responsible for the building. It turns "the fan was running at the last inspection" into proof the system is running today. CPS Calibr
…
Oct 29th 2026
Methane Monitoring in Buildings Built Over Landfills and Old Fill
A building over a landfill or old fill needs fixed methane monitoring because the ground beneath it generates landfill gas for decades: methane that migrates through soil and into the structure must be detected where it collects, with alarms set well below methane's lower explosive limit of 5% by volume — common fixed-system practice alarms at 10–25% of that limit. A vapor barrier slows the migration; fixed LEL detection and alarms are the layer that proves the occupied building is staying clear
…
Oct 29th 2026
Vapor Barrier Contractors: Who Handles Your Monitoring and Alarm Scope?
On most vapor mitigation projects, the monitoring and alarm scope — fixed methane monitors, sub-slab vacuum alarms, and telemetry — is a separate gas-detection trade from the barrier itself, and the cleanest way for a barrier contractor to deliver it is to sub it to a gas-detection shop. CPS Calibrations performs that scope as a partner sub-scope for vapor barrier and mitigation contractors: detection points, alarms, and telemetry installed, commissioned, and calibrated, quoted in writing, so th
…
Oct 29th 2026