Blog
SENSIT GOLD G2 and G3: The Leak Investigation Instruments Utilities Actually Carry
The SENSIT GOLD G2 and GOLD G3 are combustible gas investigation instruments built for utility leak work: each one ranges from parts per million (ppm) for finding a leak, through %LEL for classifying it, to %volume for purging and inert-gas work — with an internal pump, bar-hole testing, and toxic-gas and oxygen channels alongside. The G2 (from $1,440.80 at CPS) displays up to 4 gases at once; the G3 (from $3,034) displays up to 5, and adds a 2-speed pump, smart sensors, Bluetooth, and optional
…
Oct 29th 2026
Gas Detection in the Refrigeration Machinery Room: What ASHRAE 15 Requires
ASHRAE Standard 15 requires a refrigeration machinery room to contain a refrigerant detector located where a refrigerant leak would concentrate, and that detector must trigger an audible and visual alarm both inside and outside the room, activate the room's mechanical ventilation, with emergency controls located outside the room. Detection that only sounds a local beep — no outside alarm, no ventilation — does not meet the standard.
Of all the rooms in a cold storage plant, the machinery room is
…
Oct 29th 2026
Freon and Halocarbon Refrigerant Leaks in Cold Storage: The Gas That Pools Low and Displaces Oxygen
Halocarbon refrigerants — R-404A, R-449A, R-134a and their relatives, sold for decades under the Freon name — are heavier than air, so a leak pools low in pits, trenches, and low corners, displaces oxygen, and is effectively odorless at dangerous concentrations. Detecting one takes a refrigerant-specific instrument (infrared or semiconductor): a standard 4-gas monitor does not read refrigerant concentration at all, and its oxygen channel only shows the displacement after the gas has already pool
…
Oct 29th 2026
Grain Elevators and Feed Mills: Fumigant, Smoldering Grain, and Bin-Entry Air
Grain elevators and feed mills face three layered gas jobs: phosphine fumigant in treated bins — exposure limit 0.3 ppm, immediately dangerous at 50 ppm — which must be aerated and clearance-tested before any entry; carbon monoxide from grain that is heating and smoldering in storage; and bin-entry air itself, which must be tested for oxygen (deficient below 19.5%) and toxics from outside, before a worker goes in, under OSHA's grain-handling standard (1910.272).
A bin looks like the simplest str
…
Oct 29th 2026
Controlled Atmosphere Storage: The Oxygen Hazard in Produce Warehouses
A controlled-atmosphere (CA) produce room is an oxygen hazard by design: it holds oxygen at 1–3% to slow ripening, against 20.9% in normal air and an OSHA oxygen-deficient line of 19.5% — so entry without testing, door discipline, and interlocks can be immediately fatal. The protection is layered: a fixed oxygen monitor at the room, controlled and interlocked doors, a personal oxygen monitor on every worker at the door, and permit discipline for any entry.
Most gas hazards are failures — a leak,
…
Oct 29th 2026