How Long Do You Test a Confined Space Before Entry?
You test a confined space until the sample has physically traveled the sample hose and the sensors have finished responding to it — the total wait is hose travel time plus sensor response time, and the two never overlap. On typical pumped instruments that works out to about 40 seconds all-in at 10 feet of hose, about a minute at 50 feet, and 1¼ to 2 minutes at the 100-foot maximum — per sampling point, and again every time the probe moves to a new level. A reading taken sooner
…
Oct 21st 2026
What Happens If You Don't Calibrate a Gas Detector?
If you don't calibrate a gas detector, it doesn't stop working — it stops telling the truth, in the dangerous direction. Electrochemical and catalytic sensors lose sensitivity as they age, so an uncalibrated detector reads low: lose 30% of a sensor's sensitivity and it displays about 70 ppm in a real 100 ppm atmosphere, its alarms fire late because the true gas has to climb past the setpoint before the sagging display does, and a sensor that has lost enough sensitivity reads zero in gas th
…
Oct 21st 2026
What Do Gas Detector Error Codes Mean?
Gas detector error codes have no universal meaning — every brand words and numbers its faults its own way, and the exact code for your instrument is defined in its manual. But every fault falls into one of six families, and the family tells you the fix: a sensor fault is a channel the instrument can't trust (reseat it, calibrate, replace it if it stays); a calibration fault means the instrument is overdue or couldn't make the adjustment (prove the gas, then recalibrate); a pump or flow fau
…
Oct 21st 2026
Why Is My Gas Detector Chirping?
A gas detector makes two completely different sounds, and they mean opposite things. A gas alarm is loud, repeating, and insistent — flashing lights, vibration, and a gas reading on the display — and it means treat the air as dangerous until you have proven otherwise from somewhere safe. A chirp is a single short beep that repeats on a slow, regular cycle, with no gas reading behind it: that is the instrument filing a status report about itself — a low battery, a sensor at end
…
Oct 21st 2026
How Do You Convert ppm to %LEL and % Volume?
To convert between ppm, %LEL, and % volume, go through % volume: 1% by volume equals 10,000 ppm, and 100% LEL is that gas's Lower Explosive Limit expressed in % volume — so for methane, whose LEL is 5.0% by volume, 100% LEL = 5% volume = 50,000 ppm, 20% LEL = 1% volume = 10,000 ppm, and the standard 10% LEL low alarm = 0.5% volume = 5,000 ppm. The same %LEL is a different number of ppm for every gas — 10% LEL of propane is 2,100 ppm, not 5,000 — because each gas's LEL sits at a
…
Oct 21st 2026