How to Ship a Gas Detector for Calibration
Ship a gas detector for calibration like this: start the service request first — call CPS Calibrations at 865-900-8844 or start at calibration services — then pack the instrument padded and protected with its charger, any pump or sample lines that belong to the instrument, and a note inside the box with your return address and contact, and ship it to CPS Calibrations, 109 S. Front Street, Rockwood, TN 37854. Do not ship calibration gas cylinders with the instrument — CPS calibrates with its own
…
Oct 29th 2026
CO2 in Food Plants: Carbonation, Packaging, and Dry Ice
Food plants bring CO2 in on purpose three ways — beverage carbonation, modified-atmosphere packaging, and dry ice — and in all three it behaves the same way: CO2 is odorless and about 1.5 times heavier than air, so it pools at floor level in tank rooms, packaging cellars, and dry-ice storage, against an OSHA limit of 5,000 ppm, a NIOSH short-term limit of 30,000 ppm, and an IDLH of 40,000 ppm. Every room where CO2 is stored or used needs a fixed monitor mounted low, and every person entering tho
…
Oct 29th 2026
What Gas Detection Does a Food Processing Plant Need?
A food processing plant needs detection for three working gases, area by area: carbon dioxide at carbonation, modified-atmosphere packaging, and dry-ice storage (OSHA limit 5,000 ppm, and it pools at floor level), carbon monoxide at gas-fired ovens, fryers, smokehouses, and forklifts (OSHA limit 50 ppm), and ammonia at the refrigeration system (NIOSH recommended limit 25 ppm) — fixed monitors in the rooms where each gas lives, plus personal monitors for the people who enter them.
Food plants rar
…
Oct 29th 2026
Chlorine Monitoring in Chemical Plants: Storage, Loading, and the Scrubber
Chlorine monitoring in a chemical plant is a low-ppm discipline built in three places — storage, loading, and the scrubber — because OSHA's chlorine limit is a 1 ppm ceiling that may never be exceeded, NIOSH recommends 0.5 ppm, and 10 ppm is immediately dangerous to life or health. Fixed detectors sit low (chlorine is about 2.5 times heavier than air and pools), and the operator connecting a railcar or ton container wears a personal chlorine monitor ranged 0–20 ppm.
Chlorine punishes vague monit
…
Oct 29th 2026
What Gas Detection Does a Chemical Plant Need?
A chemical plant needs gas detection in two layers matched to each area's gases: fixed detectors at storage, loading racks, and process units for the plant's specific toxics — chlorine (OSHA ceiling 1 ppm), ammonia (NIOSH recommended limit 25 ppm), hydrogen sulfide, and flammable gas in %LEL — plus solvent/VOC monitoring on a PID, and a personal multi-gas monitor on every worker, because a wall sensor cannot follow a mechanic into a pipe rack, a sump, or a vessel entry.
There is no single "chemi
…
Oct 29th 2026