Community Air Monitoring During Remediation: Who Sets Up the CAMP Stations?
On a remediation site, the community air monitoring plan (CAMP) is run from perimeter stations — a photoionization detector (PID) watching total volatile organic compounds (VOCs) and a particulate monitor watching PM10 dust at the downwind edge of the work area, compared against an upwind background station on 15-minute averages. Under the model CAMP (the New York State Department of Health generic CAMP in Appendix 1A of NYSDEC DER-10), work pauses at 5 ppm of VOC over background and shuts down
…
Oct 29th 2026
Vapor Intrusion Mitigation Monitoring: The Part of the System That Proves It Works
A vapor intrusion mitigation system is only proven to work by its monitoring: continuous or logged vacuum (differential-pressure) readings under the slab, gas alarms where a specific gas drives the design, and telemetry that alerts someone when the system fails. The barrier and the fan are the mitigation — the monitoring, alarm, and telemetry scope is the separate part of the system that proves performance over the years the building is occupied.
Ask a room of project teams what a vapor intrusio
…
Oct 29th 2026
Gas Detection Data: Getting Alarms and Readings Into SCADA and Building Systems
There are four practical ways to get gas detection data into SCADA or a building system, in rising order of information: dry relay contacts, which carry alarm state only; 4–20 mA analog loops, which carry the live concentration from each point on its own pair of wires; Modbus (RTU over RS-485 serial, or TCP over Ethernet), which carries values, alarm states, and diagnostics from many points over one network; and wireless gateways, which carry the same digital data where conduit is impractical. C
…
Oct 29th 2026
The Forgotten Places: 7 Spots Plants Forget to Monitor
The seven spots plants most often forget to monitor are elevator pits, loading docks, compressor sheds, sumps, paint booths, battery rooms, and below-grade vaults — each with a predictable gas and a predictable failure: hydrogen sulfide settling into sumps and pits (NIOSH ceiling 10 ppm, IDLH 100 ppm), carbon monoxide building at docks (OSHA limit 50 ppm), hydrogen collecting at battery-room ceilings (flammable at 4%), and oxygen displaced in below-grade vaults (deficient below 19.5%). The patte
…
Oct 29th 2026
Gas Detection Training: Who Needs It, What It Covers, and How Often
There is no single OSHA standard titled "gas detector training" — the duty to train gas detector users is real, but it flows from four sources: 29 CFR 1910.146 (permit-required confined spaces), which requires training before first assigned duties and certification with the employee's name, trainer's initials, and dates; 29 CFR 1910.1200 (Hazard Communication), which requires training at initial assignment and before new chemical hazards; 29 CFR 1910.134, which requires annual retraining where r
…