What Gas Detection Does a Data Center Need?
A data center needs fixed gas detection in the rooms around the servers, not just in the data hall: hydrogen detection high in the battery room (hydrogen is flammable at 4% by volume, and fire codes design ventilation to hold it to 1%), refrigerant detection in the cooling plant machinery room as ASHRAE 15 requires, carbon monoxide detection at the generators (OSHA limit 50 ppm), and oxygen monitoring anywhere inert-gas fire suppression can displace breathable air (oxygen-deficient below 19.5%).
…
Oct 29th 2026
Who Can Calibrate My Gas Detector? GX-3R, Crowcon, SENKO & More — Calibrated In-House
CPS Calibrations in Rockwood, Tennessee calibrates RKI, Crowcon, and SENKO portable gas detectors in-house — the RKI GX-3R and GX-3R Pro, the Crowcon T4 and Gas-Pro, and the SENKO SP MGT among them — along with MSA, Honeywell (BW and RAE), and most other major brands, and you can ship your meter to our lab from anywhere in the U.S. Call (865) 900-8844 for a written quote, and a written quote right now locks your calibration pricing for 6 months.
"Who can calibrate my meter?" is usually asked und
…
Oct 29th 2026
How to Calibrate an RKI GX-3R: Fresh-Air and Span Calibration, Step by Step
To calibrate an RKI GX-3R, you make two adjustments in User Mode, in this order: AIR CAL, which sets the fresh-air zero in clean air (20.9% oxygen), and AUTO CAL, which spans all four channels at once against a 4-gas cylinder — 50% LEL methane, 12% oxygen, 25 ppm H2S, 50 ppm CO — fed through the calibration cup on a 0.25 LPM fixed-flow regulator, flowing the gas for 1 minute before the instrument sets the calibration. Anything less than both adjustments is not a full calibration; it is a bump te
…
Oct 29th 2026
SENKO SGT vs. SGT-P: Disposable or Maintainable Single-Gas Detector?
The SENKO SGT is the disposable: $163 for CO or H2S, it runs continuously for up to 24 months with no calibration and no maintenance, and at end of life you replace the whole unit. The SENKO SGT-P is the maintainable build of the same detector: $172 up front, but its sensor swaps for $121 and its battery for $21, it can be calibrated and switched off between jobs — and over 6 years of CO or H2S service the two cost nearly the same, about $489 for three SGT disposables versus about $456 to keep o
…
Oct 29th 2026
Can You Put a Gas Detector on a Tailpipe? Places a 4-Gas Meter Should Never Sample
No — a tailpipe exhaust stream runs about 300–500°F at the muffler and tailpipe in normal driving, while a typical 4-gas safety monitor such as the RKI GX-3R is rated for continuous use at −4°F to +122°F, and the stream itself defeats the sensors a second way: it is hot, wet, soot-laden, and far over range, so the catalytic LEL bead — which must burn gas with oxygen to read at all — can be damaged into reading low, and the electrochemical CO and H₂S cel
…