Blog
Gas Hazards in a Gas Processing Plant
The gas hazards in a gas processing plant follow the process itself: hydrogen sulfide (H2S) arrives with the inlet gas and concentrates in the amine unit's acid gas, sulfur dioxide (SO2) appears in sulfur recovery, and flammable gas (%LEL) is the standing risk at propane refrigeration, product storage, and loading — so fixed detectors belong at those process points full-time, while portable monitors cover the people doing permit work, entries, and sampling between them.
A gas plant is not one ha
…
Oct 26th 2026
Fixed Gas Detection for Compressor Stations
An unmanned compressor station needs fixed gas detection more than a staffed facility does, not less: with nobody on site to smell a leak, hear a hiss, or wear a portable monitor, only fixed methane (LEL) points near compressor seals and packing, valve areas, and building inlets — plus hydrogen sulfide (H₂S) points where the gas is sour — can catch a release when it starts and send the alarm to someone who is not there, through a controller relay to SCADA or telemetry, with a beacon and horn on
…
Oct 26th 2026
Tank Gauging and Thief Hatches: The Gas Hazard Nobody Sees Coming
Never gauge a production tank unmonitored: opening a thief hatch puts the gauger's face directly in the tank's vapor space, where hydrocarbon vapor can exceed the lower explosive limit (LEL) alongside benzene and hydrogen sulfide, and oxygen can be displaced below 19.5%. Stand upwind, crack the hatch, and draw the sample first with a pumped multi-gas instrument — a PID-capable monitor such as the RKI GX-6100 ($1,597–$5,152) adds the benzene picture — while wearing a personal monitor in the breat
…
Oct 26th 2026
What Gas Detectors Does a Drilling Rig Need?
A drilling rig needs three layers of gas detection: fixed LEL and H2S points at the cellar, shale shaker, and mud tanks, a personal multi-gas monitor on every floor hand, derrickman, and driller, and a pumped 4-gas unit — $835–$975 for an RKI GX-Force — to test the cellar and other low spaces before anyone enters them. No single detector covers all three jobs, because the cellar, the returns system, and the person each present the hazard in a different place.
Work the rig as a map, not a shoppin
…
Oct 26th 2026
Sour vs. Sweet Wells: How H2S Changes Your Gas Detection Program
A sour well puts a personal hydrogen sulfide (H2S) monitor on every person on location — not just the crew doing the work — and adds fixed H2S points at separators, tanks, and low spots, because at 100 ppm H2S shuts off the sense of smell, the only warning an unmonitored person has. A sweet well still needs LEL and oxygen monitoring; going sour changes the toxic picture, it does not remove the flammable and oxygen hazards that were already there.
That is the change in two sentences. Everything b
…
Oct 26th 2026