Blog
What Gas Detectors Do Wastewater Workers Need?
Wastewater workers need a pumped 4-gas detector — LEL, oxygen, CO, and H₂S — to test wet wells, manholes, and vaults before and during permit-required confined-space entry, and a single-gas H₂S detector on every operator making rounds. The pumped entry instrument runs $835–$975 (RKI GX-Force), and the rounds clip runs $137.50–$226 (Crowcon Clip SGD, disposable) — because H₂S is the gas wastewater produces first, and it deadens the sense of smell that workers instinctively rely on.
One detector c
…
Oct 26th 2026
Do You Need a Gas Detector for Welding? When Hot Work Requires Monitoring
Usually not for the welding itself — open-shop welding on its own does not normally require a personal gas detector — but hot work does require gas monitoring when the conditions around it create an atmosphere hazard: welding in or near a confined space, oxygen enrichment from a leaking oxy-fuel setup (detectors alarm high at 23.5% O₂), carbon monoxide from an engine-driven welder run indoors, or an LEL check before hot work near fuel and flammable storage.
That distinction — the arc versus the
…
Oct 26th 2026
Hydrogen Monitoring in Battery Rooms: The Detector Every Facility Forgets
Yes — a room where vented lead-acid or VRLA standby batteries charge needs fixed hydrogen monitoring: charging releases hydrogen (most heavily during equalize or boost charging), hydrogen rises and collects at the ceiling, and it is flammable at just 4% by volume, which is why fixed detectors are mounted high above the racks and typically alarm at 10–25% of LEL — 0.4% to 1.0% hydrogen by volume — with ventilation interlocked to start on alarm.
The battery room is the most commonly forgotten moni
…
Oct 26th 2026
Gas Detector Calibration and Support, 30 Minutes from Oak Ridge
CPS Calibrations calibrates gas detectors in-shop at 109 S. Front Street in Rockwood, Tennessee — about 30 minutes from Oak Ridge — at $55 for a single-gas instrument and $90 for a four- or five-gas instrument, and we calibrate every channel on the instrument. Every calibration leaves with a CPS calibration certificate and a documentation trail that includes the calibration gas used, whose cylinder QR code links to that cylinder's own SDS and Certificate of Analysis.
For facilities in and around
…
Oct 26th 2026
HF and Toxic Gas Monitoring for Fuel Fabrication and Enrichment
Where uranium hexafluoride (UF6) is handled, contact with moisture produces hydrogen fluoride (HF) — a toxic gas with an OSHA permissible exposure limit of 3 ppm as a time-weighted average and a NIOSH IDLH of 30 ppm. Fuel-fabrication and enrichment facilities therefore monitor for HF continuously at low ppm, using dedicated electrochemical fixed detectors and sample-draw systems — such as the RKI GD-70D ($1,595, HF range 0–9 ppm) — with sensing points at process equipment and cylinder storage.
T
…
Oct 26th 2026