How to Calibrate a Crowcon Portable Gas Detector: Bump, Span, and the Stations That Automate It
Calibrating a Crowcon portable gas detector is a two-part discipline: bump test the instrument before each day's use to prove its sensors respond and its alarms fire, and calibrate on schedule — zeroing the sensors in clean air, then spanning each channel against a known concentration of the correct calibration gas, delivered through the detector's calibration plate at a fixed flow of 0.5 L/min. A calibration is due on your site policy's schedule, after any failed bump test, and at least a
…
Oct 23rd 2026
Crowcon Connect Explained: What the IQ Platform Does With Your Gas Detection Data
Crowcon Connect is the cloud platform behind Crowcon's IQ range of gas detectors: it collects the alarm events, exposure records, bump-test results, and calibration records generated by IQ instruments — the single-gas UnoIQ, the two-gas DuoIQ, and the DetectiveIQ area monitor — and presents them in one dashboard with compliance status, customisable reports, and traceability for audits. The system works in three layers: the detectors themselves, which carry sensors in swappable pre-ca
…
Oct 23rd 2026
Hydrogen Gas Detection: Why H2 Breaks the Usual Rules (and Which Crowcon Detectors See It)
Hydrogen breaks the usual gas-detection rules: it is colorless and odorless, it is flammable across 4–75% by volume — the widest range of any common industrial gas — it rises and pools at ceilings instead of settling at floor level, its flame is nearly invisible, and infrared gas detectors cannot see it at all, because hydrogen has no infrared absorption signature. Crowcon answers hydrogen with five different sensing technologies — MPS, catalytic pellistor, electrochemica
…
Oct 23rd 2026
How to Plan a Fixed Gas Detection System: Detectors, Controllers, and Coverage
A fixed gas detection system is planned in three layers that have to be designed together: a sensing layer of detectors matched sensor-by-sensor to the hazard map (pellistor or infrared for flammables, electrochemical for toxics and oxygen, thermal conductivity for percent-volume gases), a control layer — a panel such as Crowcon's Vortex (4, 8, or 12 channels, $4,761–$6,579) or GMS (1 or 4 channels) — that watches every point and votes the alarms, and an action layer of relays
…
Oct 23rd 2026
What Does Cold Weather Do to a Gas Detector? Batteries, Sensors, and Readings Below Freezing
Cold weather attacks a gas detector in a set order: below −20°C (−4°F), battery runtime can fall by 50% or more, the electrochemical reactions that produce toxic and oxygen readings slow down so response time (T90) stretches past its room-temperature rating, and after extended exposure below −20°C the water-based electrolyte inside electrochemical sensors can freeze — the oxygen sensor usually first — while LCD displays turn sluggish or go blank even tho
…