Crowcon T4 Portable 4-Gas Detector: What It Detects, What It Costs, and Who It's For
The Crowcon T4 is a personal multi-gas detector that watches the four most common gas hazards — oxygen (0–30% vol), carbon monoxide (0–1,000 ppm), hydrogen sulfide (0–100 ppm) and flammable gas (0–100% LEL) — in a 282 g unit that is drop-tested to 4 m onto concrete and sealed to IP65 and IP67. Its signature features are +ve Safety™, a traffic-light indicator that shows at a glance whether the unit is working and in compliance, and TWA Resume, which keeps
…
Oct 23rd 2026
Why Does Gas Detector Data Logging Matter? The Paper Trail Your Incidents Need
Gas detector data logging matters because it is the only objective record of an incident: a data-logging detector time-stamps the readings on every channel at a set interval and separately records alarm events, peak readings, TWA and STEL exposure values, and the bump-test and calibration history that proves the instrument was working that day. The SENKO SP-MGTP ($850), for example, stores 30 alarm events, 30 calibration logs, and 30 bump-test logs alongside more than 2 months of measurement dat
…
Oct 22nd 2026
What Is a Confined Space? OSHA's Definition, the 3 Tests, and When It Becomes Permit-Required
A confined space is a space that passes all three of OSHA's tests at the same time: it is large enough and so configured that an employee can bodily enter and perform assigned work, it has limited or restricted means for entry or exit, and it is not designed for continuous employee occupancy (29 CFR 1910.146). Tanks, vessels, silos, storage bins, hoppers, vaults, and pits are OSHA's own examples. If that space also contains — or could contain — a hazardous atmosphere, engulfing mater
…
Oct 21st 2026
PID vs. LEL for VOC Detection: Which Sensor Do You Actually Need?
Use a PID to detect VOCs and an LEL sensor to detect explosive atmospheres — they measure different hazards on scales roughly 1,000× apart. A PID reads volatile organic compounds in ppm and ppb (the SENKO V-PRO resolves 0.1 ppm, and 1 ppb on its high-sensitivity range), which is where solvent exposure limits live — benzene's OSHA limit is 1 ppm. An LEL sensor reads combustible gas as a percentage of the lower explosive limit, where 100% LEL for methane is 5% by volume (50,000 p
…
Oct 21st 2026
Semiconductor (MOS) Gas Sensors: Where They Work and Where They Lie
A semiconductor (MOS) gas sensor measures gas with a heated film of metal oxide — usually tin dioxide (SnO₂) held at roughly 200–400 °C — whose electrical resistance falls when gases react with the oxygen adsorbed on its hot surface. That single resistance change is the whole measurement, and it explains both halves of the sensor's character: MOS sensors are cheap, small, sensitive, and long-lived, which is why they run residential gas alarms, A2L refrigerant leak sensors,
…
Oct 21st 2026