Blog
What Is an Area Monitor — and When Does It Beat Personal Monitors?
An area monitor is a transportable multi-gas gas detector that guards a place instead of a person: you set it at the boundary of a work zone — outside a tank entry, around a hot-work job, across a turnaround — and it samples that space continuously, with alarms built to be heard across the whole area and, on wireless models, readings shared with every other linked unit. It beats a personal monitor whenever the space needs the guard — before anyone enters it, while nobody is in
…
Oct 21st 2026
How Many Gas Detectors Does a Facility Need?
A facility needs as many gas detectors as it takes to cover its credible leak scenarios — there is no detectors-per-square-foot rule in any major standard, because a point gas detector only detects gas that physically reaches its sensor. The count is set by three things: where gas can credibly leak (flanges, valves, pump seals, compressors, loading connections), where that gas will go once it escapes (its density, plus the room's ventilation and airflow), and the coverage target set for ea
…
Oct 21st 2026
What Does SIL Mean for Gas Detection?
SIL — Safety Integrity Level — is a rating of a safety function, not of a single detector: under IEC 61508, SIL measures how reliably a complete safety loop performs when it is demanded, and a SIL 2 function must hold an average probability of failure on demand (PFDavg) of at least 0.001 but less than 0.01 — it may fail no more than about 1 time in 100 to 1,000 demands, which works out to a risk reduction factor of more than 100 up to 1,000. The rating covers the whole loop act
…
Oct 21st 2026
What Is an Ultrasonic Gas Leak Detector?
An ultrasonic gas leak detector is a fixed detector that finds leaks by listening instead of sampling: gas escaping under pressure generates broadband noise, and the detector's microphone hears the ultrasonic part of it — above the 25 kHz cutoff these instruments use to shut out ordinary audible sound — and alarms on sound pressure level, not on concentration. It reports no %LEL and no ppm, it is never calibrated with gas, and because it responds to the leak at its source, wind and v
…
Oct 21st 2026
Open-Path vs. Point Gas Detectors: What's the Difference?
The difference between an open-path and a point gas detector is what each one measures: an open-path detector runs an infrared beam between a transmitter and a receiver — typically 5 to 200 meters apart — and reports the total gas along the whole line in LEL·meters, which is concentration multiplied by cloud length, while a point detector samples the air at its own sensor and reports the exact concentration right there, in %LEL for combustibles or ppm for toxics. So an open-pa
…
Oct 21st 2026