Blog
How Do You Calibrate a BW MicroClip XL?
To calibrate a BW GasAlert MicroClip XL, take it to a safe area with a normal 20.9% oxygen atmosphere, hold the button through the OFF countdown and keep holding through the CAL countdown to enter calibration, let the detector auto-zero all of its sensors and calibrate the oxygen sensor, then — only when APPLY GAS is displayed — fit the calibration cap and apply the BW quad mix (CH₄ 2.5% / 50% LEL, O₂ 18.0%, H₂S 25 ppm, CO 100 ppm, balance nitrogen) at a flow of 250 to 500 ml/min unt
…
Oct 20th 2026
Bump Test Gas vs. Calibration Gas: Are They the Same Thing?
Yes — bump test gas and calibration gas are usually the same cylinder: a standard 4-gas mix (H₂S 25 ppm, CO 50 ppm, methane 50% LEL, O₂ 12%, nitrogen balance — $195 in a 34L cylinder at CPS Calibrations) both trips a detector's alarms for a bump test and sets its span for a calibration, because a bump test only needs each concentration to clear the instrument's alarm setpoints, while a calibration needs those same concentrations to match the instrument's span settings exactly. The tw
…
Oct 20th 2026
RKI Calibration Stations: Which Docking Station Does Your Monitor Need?
RKI calibration stations are model-specific: every SDM docking station fits exactly one instrument family and no other — the SDM-3R ($1,322) takes the GX-3R and GX-3R Pro, the SDM-04 the 04 Series and SC-04, the SDM-Force the GX-Force, the SDM-6100 the GX-6100, and the SDM-03 the older 03 Series. What each station automates is the same maintenance routine — bump test, full calibration, charging where the instrument is rechargeable, and a dated pass/fail record kept automatically &mda
…
Oct 20th 2026
How Many Calibrations Do You Get From a 34L, 58L, or 103L Cylinder?
At the common 0.5 L/min fixed flow rate, a 34L cylinder holds 68 minutes of gas flow, a 58L holds 116 minutes, and a 103L holds 206 minutes — so at 90 seconds of gas per calibration, that works out to about 45 calibrations from a 34L, 77 from a 58L, and 137 from a 103L. Those are ideal counts: real life lands below them, because a fixed-flow regulator flows the whole time it is open, tests get repeated, and the last gas in the cylinder is not all usable.
That is the short version. The rest
…
Oct 20th 2026
SENKO Fixed Gas Detectors: Which SI-Series Monitor Does Your Facility Need?
SENKO's fixed gas detectors come down to one question — how does the gas reach the sensor? The SI-200E (from $950) is an explosion-proof diffusion detector, ATEX/IECEx rated and IP66, that continuously watches the air around it for oxygen, toxic and combustible gases. The SI-301 (from $1,800) is an explosion-proof sampling detector (IP65) whose built-in pump pulls gas through up to 30 m of tubing from the point that matters into a cartridge sensor. The SI-H100 (from $1,518) is a sample-dra
…
Oct 20th 2026