Ammonia and CO2 in Poultry Houses: Barn Air Monitoring
In a poultry house, the air ages with the flock: ammonia released from litter builds week by week as litter moisture and cake accumulate — against worker limits of 50 ppm (OSHA, 8-hour TWA) and 25 ppm TWA / 35 ppm short-term (NIOSH) — while carbon dioxide from birds and heaters rides up whenever winter ventilation is throttled down to hold heat. Monitoring barn air is therefore a flock-long discipline, not a one-time test: fixed sensing where the crew works, ventilation that answers it, and spec
…
Nov 1st 2026
Your Detector Failed Calibration: What Happens Next?
When a gas detector fails calibration at CPS, four things happen in order: the failure is documented as-found — what each channel actually read against known gas before anyone adjusted anything — an adjustment is attempted, because most failures are drift and drift adjusts out; any channel that still will not come in is diagnosed down to the sensor or the hardware behind it; and anything beyond calibration is quoted to you in writing before any work happens, so the repair decision is yours, made
…
Nov 1st 2026
What Gas Detection Does a Pharmaceutical Plant Need?
A pharmaceutical plant needs gas detection in four places: LEL monitoring where solvents are stored, dispensed, and processed; fixed oxygen-depletion detection wherever nitrogen does its quiet work — blanketing, lyophilization, packaging — because inert gas drops air below the 19.5% oxygen-deficiency line with no warning at all; hydrogen detection in hydrogenation areas, placed high where hydrogen collects; and portable monitors for maintenance and entry — all of it arranged so the monitoring pr
…
Nov 1st 2026
What Gas Detection Does a Laboratory Need?
A laboratory needs gas detection matched room by room to its inventory: fixed oxygen-depletion monitoring wherever nitrogen, argon, or helium is stored or used in quantity — air below 19.5% oxygen is oxygen-deficient, and inert gases get there silently, with no smell and no warning — hydrogen (LEL) detection in GC labs, watch over cylinder cabinets and toxic-gas storage, and portable monitors for the people who move between rooms. Labs rarely lack hazards; they lack a map of them, because the ri
…
Nov 1st 2026
SENSIT Calibration Service: Mail In Your Leak Detector
Mail-in calibration for a SENSIT leak detector at CPS Calibrations covers the combustible channel verified in PPM, LEL, and percent volume as configured — the GOLD G2 (configured $1,440.80–$3,002.20) can display up to four gases at once, adding oxygen, carbon monoxide, and hydrogen sulfide channels that are each spanned on their documented gas — with as-found readings recorded before any adjustment, a sensor health check on the internal pump and sample path, and the instrument returned with a ce
…
Nov 1st 2026